DISPL AY INFORMATION DESCRIPTIONS:  

 

Status 

Description 

BOILER OFF 

Machine off. Display backlight off but temperature read-
out still working. 

FILLING ... 

Water level below low level probe. Machine is filling 
automatically. Status LED 

– 2 red blinks. 

FILL THE TANK 

Water level below low level probe. Machine has to be 
refilled manually (shown only in MANUAL mode). 
Status LED 

– 2 red blinks. 

WAIT ... 

Water is being heated. Dispense valve disabled. 

BOILER READY 

Water is up to the temperature and can be used. Note that 
this only means that the tank is heated and not that it is 
full. 
Status LED 

– green. 

DISPENSE 

Water is being dispensed. If machine is set to time 
dispense 

– there will also be a progress bar drawn 

underneath. Dispense can always be cancelled by clicking 
the dispense button again. 

COOLING ... 

Machine was set by the user to a lower temperature than 
the current tank temperature and is trying to cool down by 
taking in more cold water. This process may take between 
20 seconds to a few minutes depending on tank size and 
temperature difference. Works only in COOL FILL mode. 

DISPENSE WATER 

TO COOL THE TANK 

Machine can not take more cold water to cool the tank 
because it is full. Water needs to be dispensed to allow 
room for more cold water to come in and finish cooling 
process. 

DESCALE TANK 

Descale timer elapsed. Time to de-scale the tank. 

CHANGE FILTER 

Litres output exceeds set value. 
Time to change the water filter. 

CHECK LOW PROBE 

Low water level probe broken (disconnected). Machine 
detects high level probe signal but can not detect low level 
one. Filling is disabled. Status LED 

– 1 red flash. 

THERMISTOR S/C 

Temperature sensor (thermistor) is short circuited. 
Dispense and heater disabled. Status LED 

– 3 red 

flashes. 

ELEMENT FAILURE 

Heating element is broken. Error is triggered when after 
20 minutes of heating and not taking in water temperature 
in the tank fails to increase. 
Dispense is disabled. Status LED 

– 4 flashes. 

THERMISTOR O/C 

Temperature sensor (thermistor) is disconnected. 
Dispense and heater disabled. Status LED 

– 5 red 

flashes. 

LOW PRESSURE 

Incoming water pressure too low. The error will be reset 
after water supply restores. 
All boiler functions are active. Status LED 

– 6 flashes. 

COMM ERROR 

Display board lost communication with boiler PCB (can 
not receive serial data about temperature and probes). 
All actions cancelled. 

 

Содержание 1000674

Страница 1: ...ax 4EF8 E337347 4JD5 Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353 0 1 295 2674 Ireland Fax 353 0 1 295 3715 email sales marco ie www marco ie UK Tel 44 0 2072 744 577 UK Fax 44 0 2079 788 141 email sales marco bev co uk www marco bev co uk ...

Страница 2: ...dren should be supervised to ensure that they do not play with the appliance In the event any wires are damaged such wires can only be replaced by experts or professional after service staff from the manufacturer after service department or similar function departments INSTALLATION DETAILS Electrical installation Electrical specification Machine type Rated power Plug type 1000677US 1000678US 2 9kW...

Страница 3: ...Y The Boiler may now be used to dispense Hot Water to the preset factory settings o 95ºC o Push and Hold operation o Continuous flow no pulsing o Auto Heat Fill Mode NOTE Because the boiler is electronically controlled no priming is necessary The element cannot switch on until a safe level of water is reached EcoSmart FEATURES The EcoSmart Ecoboiler has many settable features which gives the opera...

Страница 4: ...en view Description Default value No 1 Sets new tank temperature NOTE Temperature should never be set for more than 97 C because it may cause steam to be generated during the low pressure days Range 60 98 5 C Resolution 0 5 C 95 0 No 2 Sets dispense time Range 0 99 9 seconds 0 1 sec resolution 100 600 seconds 1 sec resolution For PUSH HOLD mode set to 0 default 00 0 No 3 Sets number of pauses duri...

Страница 5: ...s is a factory setting and should only be changed by trained personnel Range 0 20 0 seconds Resolution 0 1 second 3 0 2 8kW 6 0 5 6kW 9 0 8 4kW No 4 Sets the time at which machine waits for the water too cool down after water intake Measured from the beginning of the water intake The value depends on tank size and element power This is a factory setting and should only be changed by trained person...

Страница 6: ...in COOL FILL mode DISPENSE WATER TO COOL THE TANK Machine can not take more cold water to cool the tank because it is full Water needs to be dispensed to allow room for more cold water to come in and finish cooling process DESCALE TANK Descale timer elapsed Time to de scale the tank CHANGE FILTER Litres output exceeds set value Time to change the water filter CHECK LOW PROBE Low water level probe ...

Страница 7: ...erate at half the capacity eg 10L boiler to operate as a 5L boiler MANUAL FILL if the boiler is not plumbed into a water supply the operator must select Manual Fill mode for best operation of the boiler In this mode the water is added manually by the operator ECO MODE OPERATION Note In the COOL FILL mode see Service setup setting No 5 the ECO Mode is automatically selected All ECO Boilers use high...

Страница 8: ...ds Remove as much scale as possible by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Follow instructions carefully Thoroughly clean and flush the machine before re use Follow installation and first time operation instructions CLEANING The exterior of these machines may be c...

Страница 9: ...arranty Fitting a scale reducer is recommended especially in hard water areas This can reduce the build up of scale but may not stop it altogether The frequency that descaling is required depends on the local water supply hard water areas need more attention Descaling of the machine should ideally be carried out by qualified service personnel ...