background image

9

www.

imPower

Dealer

.com

9

Two Speed Connections with Timer 

If you had a single speed motor prior to this installation, you will need to run new 

conduit with 4 wires (High Speed, Low Speed, Neutral, and Ground) to properly 

operate with the two speed timer.

Step 1:

  Remove the three screws holding the top control enclosure onto the  

motor.  Carefully lift the top panel and turn it over to expose the inside of the 

terminal box. 

Step 2: 

 Run the HIGH SpeedLOW SpeedL2, and GROUND wires from the  

conduit cable through the open on the right side of the motor (shaft facing  

away from you). 

Step 3:

  Connect the wire for the HIGH Speed from the timer to the opening 

directly across from the BLACK wire on the terminal block. 

Step 4: 

 Connect the wire for the LOW Speed from the timer to the opening  

directly across from the RED wire on the terminal block. 

Step 5:

  Connect the L2 to the opening directly across from the WHITE wire  

on the terminal block. 

Step 6:

  Connect the GROUND to the opening directly across from the  

GREEN/YELLOW wire on the terminal block. 

Step 7

:  Screw in the conduit connector into the terminal box on the right side of  

the terminal box (shaft facing away from you). 

Step 8:

  Carefully fold the extra wires inside the terminal box and place the  

top control panel back on top of the terminal box. 

Step 9:

  Tighten the three screws into the terminal box while applying light  

pressure to the top control enclosure. 

- 1 -

Safety Considerations

The following definitions are used as safety considerations on the 

Evergreen IM motor and in this manual. Please read and observe all  

of these safety concerns. 

SAFETY 

SYMBOLS

Installation and service of this motor should be attempted only by  

trained service technicians familiar with the Evergreen instructions  

and training manual. 

This motor should be installed in accordance with accepted practices  

and installation instructions, and in compliance with all national and  

local codes. 

 REG7232_EvergreenIM_Reprint.indd   1

4/28/10   2:05:19 PM

When servicing the pool pump filter motor, always disconnect the main  

power from the unit.  It is also good practice to confirm that the power is off 

with a meter.

Содержание imPower

Страница 1: ......

Страница 2: ...is not only saves the Earth s precious resources but also saves the consumer hundreds of dollars per year in energy costs Why Choose Us Our fast response to customer questions unmatched engineering ex...

Страница 3: ...the Existing Motor from Pump 6 Single Speed Connection with Timer 7 Two Speed Connections with Timer 9 Automation Controller Signal Line Connection 11 Changing Default Low Speed 14 imPower Motor Conne...

Страница 4: ...be attempted only by trained service technicians familiar with the Evergreen instructions and training manual This motor should be installed in accordance with accepted practices and installation inst...

Страница 5: ...three selectable speeds either through the use of the patent pending auto speed switch feature top panel push buttons external multi speed timers or through external automation controls RB003 Model Nu...

Страница 6: ...se the seal from the existing motor when installing the imPower motor Remove the screw holding the seal plate onto the motor Step 5 Remove the pump motor by removing the four bolts holding the motor t...

Страница 7: ...n the right side of the terminal box shaft facing away from you Step 7 Carefully fold the extra wires inside the terminal box and place the top control panel back on top of the terminal box Step 8 Tig...

Страница 8: ...d for 2 hours and then the motor will automatically switch to the low speed Note in the installation manual there is a section that will show you how to change the default low speed setting The total...

Страница 9: ...opening directly across from the WHITE wire on the terminal block Step 6 Connect the GROUND to the opening directly across from the GREEN YELLOW wire on the terminal block Step 7 Screw in the conduit...

Страница 10: ...y power to the motor This connection allows the high speed and low speed to be operated at any dura tion set by the multi speed timer At no point will the motor automatically do down to the default lo...

Страница 11: ...tly across from the GREEN YELLOW wire on the terminal block Step 6 Screw in the conduit connector into the terminal box on the right side of the terminal box shaft facing away from you Step 7 On the r...

Страница 12: ...rol panel Step 14 Replace and tighten the screws to mount the seal plate onto the motor Step 15 Put a NEW pump seal into the seal plate and onto the motor shaft Handle and lubricate seal per manufactu...

Страница 13: ...he automation controller via the buttons on the top control panel The override will continue until the motor is either powered off by the automation controller or a new speed is requested by the autom...

Страница 14: ...within the first two minutes of operation The low speed LED will blink for three seconds followed by 15 blinks of the medium speed LED The low speed LED blinks for three seconds to identify that the...

Страница 15: ...15 www imPowerDealer com 15 imPower Motor Connection Diagram Accessories Description P N 15 ft Low Voltage Cable 391 200 01 25 ft Low Voltage Cable 391 200 02...

Страница 16: ...Need Additional imPower Help Contractor Hotline 800 683 9144 imPower Website www imPowerDealer com...

Отзывы: