![Marantz SR6006/K1B Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/marantz/sr6006-k1b/sr6006-k1b_service-manual_1725764024.webp)
24
3. DUAL BACKUP MEMORY
This product has a Dual Backup Memory function. The conventional Backup functions to memorize, in the EEPROM
(IC202) in the circuit, a current setting of the moment the main power is turned off so that it can be restored when it
is turned ON again. Meanwhile, the DUAL BACKUP MEMORY is capable of memorizing any arbitrary setting that is
configured while the product is in operation so as to restore it at any time. When servicing units returned from end-users
for repairs, use this function to back up the current setting (e.g. Tuner Preset). This will enable the units to be returned to
the users after repairs, with the setting unchanged.
s
NOTE:
If end-users use this function, the data will be overwritten.
The contents of the memory do not disappear even if you initialize this unit.
If you want to erase, please refer to
3.2. SERVICE PRECAUTIONS
.
3.1. HOW TO OPERATE
-Backup-
(1) Configure a setting you would like to save in the MEMORY and hold down the "M-DAX" and "STATUS" buttons on
the Front Panel at the same time for 3 seconds or more.
(2) The FL Display indicates "MEMORY SAVING" while the Recovery is being performed.
FLD
M E M O R Y
S A V I N G
(3) The FL Display indicates "COMPLETE" when the Backup is completed.
FLD
C O M P L E T E
-Recovery-
(1) Hold down the "M-DAX" and "DISPLAY" buttons at the same time for 3 seconds or more.
(2) The FL Display indicates "MEMORY LOAD" while the Backup is being performed.
FLD
M E M O R Y
L O A D
(3) After the FL Display indicates "COMPLETE", the product goes into Standby mode. When the power is restored, the
Recovery is completed.
FLD
C O M P L E T E
The FL Display indicates "NO BACKUP" if the DUAL BACKUP MEMORY has not been activated with no data to be
recovered saved in the Memory.
FLD
N O
B A C K U P
3.2. SERVICE PRECAUTIONS
When the Flash Rom (IC202) on the HDMI PWB is replaced make sure, in order to maintain consistency with the Backup
Memory, to clear the DUAL BACKUP MEMORY in thefollowing way :
s
-Backup Memory Clear-
(1) Hold down the "M-DAX" and "ZONE SELECT" buttons at the same time for 3 seconds or more.
(2) The FL Display indicates "BACKUP CLEAR" while the memory is being cleared.
FLD
B A C K U P
C L E A R
(3) After the FL Display indicates "COMPLETE", the operation is completed.
FLD
C O M P L E T E
Содержание SR6006/K1B
Страница 14: ...14 3 Disconnect the connector wire Remove the screws 4 Remove the screws CN931...
Страница 60: ...Personal notes Personal notes 60...
Страница 81: ...81 I2C communication wave form CH1 CLK CH1 DATA...
Страница 157: ...157 Personal notes Personal notes...
Страница 167: ...167 R5F3650KNFB HDMI IC231...
Страница 176: ...176 W9864G6JH 6 HDMI IC409 W9864G2IH Publication Release Date Aug 28 2009 4 Revision A03 4 PIN CONFIGURATION...
Страница 179: ...179 MX29LV160DBTI 70G HDMI IC410 MX29LV160DBTI 70G Block Diagram...
Страница 180: ...180 AK4424ET HDMI IC455 IC457 AK4424ET Block Diagram...
Страница 181: ...181 AK5358BET HDMI IC451 AK5358BET Pin Function...
Страница 185: ...185 W9825G6JH 6 HDMI IC392 W9825G6JH 6 Pin Function...
Страница 192: ...192 NJW1194A AUDIO IC484 IC489 BLOCK DIAGRAM...
Страница 193: ...193 2 FL DISPLAY VFD GP1261AI FRONT Z1002 PIN CONNECTION PATTERN DETAIL...
Страница 225: ...225 Personal notes...