2. Errors checking mode (Displaying the protection history)
2.1. Operation specifications
Error mode (Displaying the protection history):
When the set is started up in this mode, the error information is displayed.
Starting up:
Press the "ON/STANDBY" button to turn on the power while pressing the "INTERNET RADIO" and "ONE TOUCH PLAY"
buttons. The error (protection history display) mode is set.
Now, press the "STATUS" button to turn on the FL display.
2.2. About the display on the FL display
When the "STATUS" button is pressed after the error (protection history display) mode is set, a history like the one shown
below is displayed, depending on the conditions.
(1) Normal (when there has been no protection incident)
FLD
P R O T E C T
H I S T O R Y
: N O
(2) For ASO (when the last protection incident was ASO protection)
FLD
P R O T E C T
H I S T O R Y
: A S O
Cause:
The line between speaker terminals is shorted, or speakers with impedance of less than the rated value.
Supplementary information:
As the excess current is detected after operation of the speaker relay, a short on the
speaker terminal and the connected speaker can be identified.
If the power is turned on without correcting the abnormality, the protection function will work about 5 seconds later
and the power supply will be shut off.
(3) For DC (when the last protection incident was DC protection)
FLD
P R O T E C T
H I S T O R Y
: D C
Cause:
DC output of the power amplifier is abnormal.
If the power is turned on without correcting the abnormality, the protection function will work about 5 seconds later
and the power supply will be shut off.
(4) For THERMAL (when the last protection incident was THERMAL
*
FLD
P R O T E C T
H I S T O R Y
: T H M
*
*
: A
~ D
Cause:
The temperature of the heat sink is excessive.
If the power is turned on without correcting the abnormality, the protection function will work about 5 seconds later
and the power supply will be shut off.
b
Additional causes of protection can be due to loose connections, associated components, Microprocessor, etc.
When the "STATUS" button is pressed again after the protection history as shown above is displayed, the normal display
Содержание SR6006/K1B
Страница 14: ...14 3 Disconnect the connector wire Remove the screws 4 Remove the screws CN931...
Страница 60: ...Personal notes Personal notes 60...
Страница 81: ...81 I2C communication wave form CH1 CLK CH1 DATA...
Страница 157: ...157 Personal notes Personal notes...
Страница 167: ...167 R5F3650KNFB HDMI IC231...
Страница 176: ...176 W9864G6JH 6 HDMI IC409 W9864G2IH Publication Release Date Aug 28 2009 4 Revision A03 4 PIN CONFIGURATION...
Страница 179: ...179 MX29LV160DBTI 70G HDMI IC410 MX29LV160DBTI 70G Block Diagram...
Страница 180: ...180 AK4424ET HDMI IC455 IC457 AK4424ET Block Diagram...
Страница 181: ...181 AK5358BET HDMI IC451 AK5358BET Pin Function...
Страница 185: ...185 W9825G6JH 6 HDMI IC392 W9825G6JH 6 Pin Function...
Страница 192: ...192 NJW1194A AUDIO IC484 IC489 BLOCK DIAGRAM...
Страница 193: ...193 2 FL DISPLAY VFD GP1261AI FRONT Z1002 PIN CONNECTION PATTERN DETAIL...
Страница 225: ...225 Personal notes...