8
Channel
Measuremet
Point Point
Surround Left
CN61
VR81
Center
CN61
VR81
Surround Right
CN61
VR81
Front Left
CN61
VR81
Surroud Back Left
CN61
VR81
Front Right
CN61
VR81
After Turning ON
Time Table of Idling Current Rise
DC voltmeter........Connect to CN61
Measurement Voltage
12.0 mV ± 0.5 mV
13.0 mV ± 0.5 mV
13.0 mV ± 0.5 mV
13.2 mV ± 0.5 mV
13.4 mV ± 0.5 mV
13.5 mV ± 0.5 mV
(CN61)
Alignment
10 min
20 min
30 min
40 min
50 min
5 min
Surroud Back Right
No.
1
2
3
4
5
6
7
CN61
VR81
13.5 mV ± 0.5 mV
60 min
MAIN PWB
CUP11928Z
BIAS T.R.
PWB
3. POWER AMPLIFIER ADJUSTMENT
Idling Current Alignment
1. Each of the measurement points are provided with the
two test points. Set a digital Voltage meter to DC voltage
input, connect the meter to the test points at both
contact points.
2. After the setup above, turn on the main switch.
3. Adjust variable resistors (VR81) according to the digital
voltmeter readings. The target setting value is the
following table for each channels.
Settings :
Master Volume — Minimum
Speaker out
— No Load
Top lid
— OPEN
アイドリング電流調整
1.
電源を
ON
する前にそれぞれの
"+"
端子と
"-"
端子間にデ
ジタルボルトメーターを接続します。デジタルボルトメー
ターを
DC
電圧入力にセットします。
2.
上記のセットアップの後に、本機の電源を
ON
します。
3.
デジタルボルトメーターの電圧値を監視しながら可変抵抗
器
(VR81)
を調節します。
各チャンネルの目標値は下記の表を参照下さい。
セッティング
:
マスター・ボリューム
̶
最小
スピーカー接続
̶
無し
トップカバー
––
無し
Содержание SR-3001
Страница 22: ...22 21 8 BLOCK DIAGRAM 07 2 4 07 054 07 6 07 45 2 5 0 4 07 054 07 03 9 32 9 ...
Страница 24: ...26 25 2 0 4 07 4 054 07 2 054 07 INPUT PWB 2 3 ...
Страница 25: ...27 28 4 07 4 2 4 07 4 6 07 4 0 4 07 50 4 INPUT PWB 3 3 ...
Страница 27: ...31 32 VIDEO PWB 4 054 07 4 6 07 4 0 4 07 2 054 07 4 054 07 2 45 2 5 4 054 07 32 ONLY COMPONENT PWB ...
Страница 28: ...34 33 4 07 4 07 2 0 7 2 42 3 07 2 054 07 ENCORDER PWB FRONT PWB H P PWB PUSH SW PWB TACT PWB ...