ENGLISH
43
How to use the RS-232C connector
This input/output connector (D-Sub 9-pin female) is used for
RS-232C external control.
A straight cable available on the market can be connected to
this connector to exercise external control and send status
information.
•
Connector pin assignment
•
RS232C Connection
The wiring requirements for a 9 pin to 9 pin serial connection,
are a male to female straight cable.
•
RS-232C physical specifications
•
Command reception
The command packets have a data length of 5, 6 or 7 bytes.
ASCII codes from 0x00 to 0x7f are used to receive serial data.
At the transmission end, therefore, take steps to convert the
ASCII codes into HEX data to set the data in the data packets.
CR (0x0d) is added as the data packet delimiter.
1
NC
2
TX
3
RX
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC
6
9
5
1
Cable
Straight cable
Baud rate
9600 bps
Data bits
8 bits
Parity bit
None
Stop bit
1 bit
Flow control
None
Command
Code
Command
Code
0
2000
Pitch Down Start
2039
1
2001
Pitch Down Stop
203901
2
2002
Program
2041
3
2003
AMS
2043
4
2004
Open/Close
2045
5
2005
Pause
2048
6
2006
Cancel
2049
7
2007
Fast Backward Start
2050
8
2008
Fast Backward Stop
205001
9
2009
Fast Forward Start
2052
Time
2011
Fast Forward Stop
205201
Recall/Scroll
2015
Play
2053
Random
2028
Stop
2054
Repeat
2029
A-B
2059
Next
2032
Display (Dimmer)
2071
Previous
2033
Menu
2082
Index +
2034
Enter
2087
Index -
2035
Text
2088
Pitch Reset
2037
Quick Replay
205304
Pitch Up Start
2038
Cue
205910
Pitch Up Stop
203801
•
Status transmission
The status packets have a fixed data length of 4 bytes.
ASCII codes from 0x00 to 0x7f are used to transmit serial
data. For this reason, the ASCII codes are converted into
HEX data before the data is set in the data packets and
transmitted. CR (0x0d) is added as the data packet delimiter.
Received command data
Example: Reception Time Command (code 2011)
2
0
1
1
CR
0x32
0x30
0x31
0x31
0x0d
Transmitted status data
Status
Code
Description
Power On
PWON
Transmitted when the power is turned on.
Tray Open
TROP
Transmitted upon completion of tray open.
Tray Close
TRCL
Transmitted upon completion of tray close.
TOC Error
TOCE
Transmitted when a TOC read error has occurred.
TOC Reading
TOCR
Transmitted when TOC read is started.
No Disc
NODI
Transmitted when “No disc” is detected.
Stop
STOP
Transmitted when the disc has stopped.
Play
Pxxx
Pause
Axxx
Fast Forward
FFON
Transmitted when Fast Forward is started.
Fast Backward
RWON
Transmitted when Fast Backward is started.
Repeat Off
RPOF
Transmitted when Repeat Off is set.
Repeat All
RPAL
Transmitted when Repeat All is set.
Repeat One
RPON
Transmitted when Repeat One is set.
Repeat A
RPA-
Transmitted when Repeat A is set.
Repeat AB
RPAB
Transmitted when Repeat A-B is set.
End Warning
ENDW
Transmitted when End Warning is started.
Transmitted along with the track number (xxx)
when play is started; also transmitted when
the track number is changed during play.
Transmitted along with the track number (xxx)
when the pause status is established.
Example 1: Transmission Power On (code PWON)
P
W
O
N
CR
0x50
0x57
0x4f
0x4e
0x0d
OTHER FUNCTIONS
PMD325
Typical HOST
Transmit Data
Receive Data
Ground
Rx Data
Tx Data
Ground
2
3
5
2
3
5
D-Sub 9 Pin
(male)
D-Sub 9 Pin
(female)
When transmitting commands consecutively, put more than
100ms blank between commands.
Downloaded from
www.Manualslib.com
manuals search engine
Downloaded From DvDPlayer-Manual.com Marantz Manuals