Maple Systems OIT3200 Скачать руководство пользователя страница 2

2

OIT3200/3250

1010-0081A, REV 04

COPYRIGHT NOTICE

This manual is a publication of Maple Systems, Inc., and is provided for use by its customers only. The

contents of the manual are copyrighted by Maple Systems, Inc.; reproduction in whole or in part, for use

other than in support of Maple Systems equipment, is prohibited without the specific written permission

of Maple Systems.

WARRANTY

Maple Systems warrants each product to be free from electrical and mechanical defects in materials and

workmanship for a period of one year from the date of shipment. This warranty does not apply to defects

in the Products caused by abuse, misuse, accident, casualty, alteration, negligence, repair not authorized

by Maple Systems, use on current or voltages other than specified by Maple Systems, or application or

installation not in accordance with published instruction manuals. This warranty is in lieu of any other

warranty either expressed or implied.
Maple Systems’ liability is limited to the repair or replacement of the Product only, and not costs of

installation, removal, or damage to user’s property or other liabilities. If Maple Systems is unable to

repair or replace a nonconforming Product, it may offer a refund of the amount paid to Maple Systems

for such Product in full satisfaction of its warranty obligation. Maximum liability of Maple Systems is

the cost of the Product.
Information furnished by Maple Systems, Inc., is believed to be accurate and reliable. However, no

responsibility is assumed by Maple Systems for the use of this information nor for any infringements of

patents or other rights of third parties which may result from its use. No license is granted by

implication, or otherwise, under any patent or patent rights of Maple Systems, Inc. Maple Systems

retains the right to revise or change its products and documentation at any time without notice.

IF SERVICE IS REQUIRED

Package the unit in its original packaging container or, if unavailable, any suitable rigid container. If a

substitute container is used, surround the unit with shock absorbing material; damage in shipment is not

covered by the warranty. Include a letter with the unit describing the difficulty and designating a contact

person. Send to the following address: Maple Systems, Inc., 808 134th Street SW, Suite 120, Everett,

WA 98204.
Only Products that have been issued a Return Material Authorization (RMA) number from Maple

Systems may be returned. All RMAs must be accompanied with a written purchase order for tracking

purposes or, in the case of out-of-warranty repairs, for repair charges on a time and material basis.
All returns will be tested to verify customer claims of noncompliance with the product warranty.

Improper return packaging which makes verification impossible will void the warranty. Products

passing the tests will be returned “AS IS” to the customer.
If noncompliance is verified and is not due to customer abuse or the other exceptions described with

product warranty, Maple Systems will, at its option, repair or replace the Product returned to it, freight

prepaid, which fail to comply with the foregoing warranty, provided Maple Systems is notified of such

noncompliance within the one-year warranty period.

APPLICATIONS ASSISTANCE

This manual is designed to provide the necessary information for trouble-free installation and operation

of your new Operator Interface Terminal (OIT). However, if you need assistance, please call Maple

Systems at 425-745-3229 or visit our web site at www.maple-systems.com.

Содержание OIT3200

Страница 1: ...LARM DOWN MESSAGE PAGE UP NEXT LAST MESSAGE TOGGLE HELP SETUP DELETE CLEAR E N T E R F1 F5 F9 F2 F6 F10 F3 F7 F11 F4 F8 F12 2 3 4 6 5 7 8 MESSAGE ALARM RUN PRINT 1 0 7 4 8 5 1 2 9 6 3 PAGE ACK ALARM D...

Страница 2: ...icense is granted by implication or otherwise under any patent or patent rights of Maple Systems Inc Maple Systems retains the right to revise or change its products and documentation at any time with...

Страница 3: ...0 When power is first applied the OIT s display will indicate that it needs to be configured Use the OITware 200 or STEPware 100 software to create a file or project that can be downloaded to the OIT...

Страница 4: ...to handling the OIT Handling the OIT at static free grounded work stations Connecting the chassis of the OIT to a clean ground Placing the OIT into an anti static bag during transport Unpacking the U...

Страница 5: ...t OIT to Power 11 2 6 Connect OIT to PLC Host 12 3 OIT Configuration Wiring 13 3 1 Connect OIT3200 to PC for Configuration 13 3 2 Connect OIT3250 to PC for Configuration 14 4 OIT3250 Special Features...

Страница 6: ...d from the hinged control panel to the rest of the enclosure 1 2 Power Supply Selection The power supply used to power the OIT should have an output between 12 and 30 VDC The voltage should measure be...

Страница 7: ...inches 20 cm of separation between the OIT cables and other power wiring If voltages greater than 120 VAC are used in the system greater separation is required If theOIT cables must come near ACwiring...

Страница 8: ...wer two pins of a 3 pin header This is called Position A 3 Move the jumper to the upper two pins of the 3 pin header Position B Ensure that the jumper is pressed fully into place 4 Replace the rear co...

Страница 9: ...o Panel INSTALLATION MANUAL 9 1010 0081A REV 04 This area to be free of paint 5 15 0 01 130 8mm 0 3 Corner drill permissable 4 70 0 03 6 00 0 01 152 4mm 0 3 8 00 0 03 1 00 ref 25 4mm 0 23 ref on REAR...

Страница 10: ...Panel The green ground wire assembly supplied with the OIT must be installed as shown This provides a good earth ground connection to the OIT s bezel and rear cover If your control panel is metal be s...

Страница 11: ...to the OIT power supply 3 The power cable should not be any longer than necessary If needed a cut the power supply cable to the appropriate length b strip the cable shield back on the power cable c s...

Страница 12: ...ide or the STEP1 Protocol Operation Manual forinformation onconstructing OIT to ASCII host communication cables STEPS 1 Connect the DE9P plug end of the communication cable to Port 1 on the OIT which...

Страница 13: ...OIT to the computer using an RS 232 serial communications cable P N 7431 0049 purchased separately from Maple Systems The configuration cable should be connected to the proper COM port on your comput...

Страница 14: ...the serial port farthest away from the power connector on the OIT3250 See Figure 10 below for Port 2 pin assignments NOTE Be particularly careful during wiring that Pins 8 and 9 on Port 2 are left ope...

Страница 15: ...hen the OIT is configured Consult the OITware 200 manual for more information Connection to the printer varies depending upon the pinout of the printer See Figure 11 for the OIT Port 2 pin assignments...

Страница 16: ...rnal Alarm Keypress Buzzers Outputs provided on Port 2 of the OIT3250 allow connections for external keypress and alarm buzzers The alarm buzzer output Pin 8 can be used to turn on an external buzzer...

Страница 17: ...e is exposed to possible damage byelectrostatic discharge Refer toStatic Awareness onpage 4 2 Find the coin cell on the PCB It looks like a 1 2 inch 12 7 mm silver disk 3 Insert a small screwdriver in...

Страница 18: ...e made on any non glossy stock between 0 004 inches 0 1 mm and 0 008 inches 0 2 mm thick by either of the following methods Photocopy the blank legends and hand illustrate Use the dimensions to create...

Страница 19: ...81A REV 04 Middle Left 1 3 Right 2 Check Dimension 4 00 101 6 mm Tick marks indicate edge of viewable area F4 F8 F3 F2 F1 F7 F6 F5 F12 F11 F10 F9 Reads this way Function Keys and Logo Product ID Figur...

Страница 20: ...on glossy stock which is 0 004 0 008 inches 0 1 0 2 mm thick Check printing accuracy with a printed check dimension 20 OIT3200 3250 1010 0081A REV 04 1 12 F8 Middle 0 50 Left 0 10 2 5 1 F4 3 F12 Right...

Страница 21: ...refer to Figure 18 6 Carefully remove the factory installed legends 7 Slide in the new legends be gentle avoid wrinkling which makes it hard to push the legend in if the legend moves around too much p...

Страница 22: ...t Liquid Crystal Display LCD 5 x 7 dot matrix with cursor Display Character Size 2 lines by 40 characters 0 2 inches 5 mm high Display Viewing Angle Approximately 120 degrees LEDs 24 for keypress and...

Страница 23: ...F3 F7 F1 F5 Alarm Message 1 Next Message Down Page Page Up Help 7 Setup 4 Ack Last Print Screen 2 3 N 9 Toggle 0 8 R E T 6 5 E Delete Clear 152 4 6 00 9 25 234 9 49 5 1 95 9 7 0 38 2 45 62 1 3 33 4 8...

Страница 24: ...K RED WIRE LIST Pin Shield 30 1 50 0 5 BLK SHIELD 3 RED 2 1 Power Connector 3 1 2 Signal Chassis Ground Signal Ground 12V to 30VDC OIT Push stripped wire into ROUND holes while holding clamps open wit...

Отзывы: