background image

Mantracourt Electronics Limited

 T24-RM1 User Manual     

 

19

 Approvals 

 

CE 

 

Complies with EMC directive. 2004/108/EC 
The Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive, 
1999/5/EC, 
 

European Community, Switzerland, Norway, Iceland, and Liechtenstein  

 

English:  

This equipment is in compliance with the essential requirements and other relevant provisions of 
Directive 1999/5/EC.  

Deutsch:  

Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden 
Vorgaben der Richtlinie 1999/5/EU.  

Dansk:  

Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i 
Directiv 1999/5/EF.  

Español:  

Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 
1999/5/EC.  

Français:  

Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la 
Directive 1999/5/EC.  

Íslenska:  

Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.  

Italiano:  

Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 
1999/5/EC.  

Nederlands:   Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 

1999/5/EC.  

Norsk:  

Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-
directiv 1999/5/EC.  

Português:   Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.  

Suomalainen: Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin 

ehtojen mukainen.  

Svenska:  

Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta 
bestämmelser i Direktiv 1999/5/EC.  

 
This equipment is in compliance with the essential requirements and other relevant provisions of Directive 
1999/5/EC.  

 

   

 

 

FCC 

 

Family: RAD24 
Models: i and e for internal and external antenna variants. For antenna T24-ANTA and T24-ANTB 
FCC ID:VHARAD24 
This device complies with Part 15c of the FCC Rules. Operation is subject to the following two conditions: (1) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation. 

 

CAUTION:

 If the device is changed or modified without permission from Mantracourt Electronics Ltd, the user 

may void his or her authority to operate the equipment. 

 

 

 

Содержание T24-RM1

Страница 1: ...T24 RM1 Relay Module User Manual www mantracourt co uk...

Страница 2: ...es 6 Setup Base Station Communications 6 Home 7 Analyser 8 Information 9 Channel and Encryption 10 Save and Restore 11 Input Settings 12 Relay Operation Settings 13 Relay Settings Advanced 15 Errors I...

Страница 3: ...d as a 6 character hexadecimal number consisting of the digits 0 to 9 and the letters A to F I e FFD3BE Data Tag Identifies each Data Provider message A Data Tag consists of a 4 character hexadecimal...

Страница 4: ...the appropriate toolkit software LEDs Mode Flashes 2 x per second when operational Activity Flashes when T24 data packets are received Time Out No T24 data present for longer than user defined period...

Страница 5: ...ined T24 device that causes the relay output to trigger Triggering of digital input 1 or 2 switch input which if configured reset latched relays Arrival of data from a specified data tag can reset lat...

Страница 6: ...ices Installation T24 Toolkit To configure the devices we must use the T24 Toolkit software application This can be downloaded from our web site or may be shipped with your products Install this on a...

Страница 7: ...d select 1 as the Base Station Address In the toolkit all items that can be changed by the user are coloured orange To change a value just click on the relevant orange item You will then be presented...

Страница 8: ...dure Remove power from the T24 RM1 module Click the Pair button on the toolkit You now have 10 seconds to re apply power to the T24 RM1 module If you connect successfully the toolkit will change to th...

Страница 9: ...or communications issues This page shows the radio signal levels detected across all the channels available to the T24 series of devices Using this tool may help in detecting noisy areas and allow you...

Страница 10: ...ed T24 RM1 User Manual 9 Information This page shows you information about the connected device Items you can change Name You can enter a short descriptive name 11 characters which may help you recogn...

Страница 11: ...s Items you can change Channel Select a channel between 1 and 16 The default is channel 1 You can use the Spectrum Analyser mode to determine a good clean channel to use NOTE Channel 16 is used to neg...

Страница 12: ...the configuration file to All configuration information including calibration data will be saved to the file The file extension is tcf Restore Click this button to open a file dialog window to allow...

Страница 13: ...hether the relay will activate See the Relay Operation Settings section for details Items you can change Relay1DataTag 1 8 Enter up to eight Data Tags the data from which will be used to determine the...

Страница 14: ...compared to the setpoint i e If any of the individual acquisition modules exceed the setpoint Difference The difference between the lowest and highest values of all the Data Tags is calculated and thi...

Страница 15: ...tronics Limited T24 RM1 User Manual 14 Operation and Hysteresis Settings Normal Operation Inverted Operation _________ RELAY ENERGISED RELAY DE ENERGISED Set Point Hysteresis OPTIONAL LATCH OPTIONAL L...

Страница 16: ...zero to disable this feature Waker Duration Enter a time in milliseconds for this module to attempt to wake acquisition modules when first powered up The default is 12000 milliseconds 12 seconds When...

Страница 17: ...upon error detection can be defined as Hold Last State De Energise Relay Energise Relay Error Mode The error mode defines what is causes the alarm relay and individual error action to be triggered Err...

Страница 18: ...ials for product enclosures preference should be given to fibreglass light coloured ABS or Polypropylene at the wavelength of 2 4GHz radio other materials will adversely affect the signal by attenuati...

Страница 19: ...dio Frequency 2 4000 2 4835 GHz Power 1 mw Range 200 650 Metres feet Channels DSSS 16 Maximum range achieved in open field site at a height of 3 metres above ground T24 RM1 Min Typical Max Units PSU 9...

Страница 20: ...tiva 1999 5 EC Nederlands Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999 5 EC Norsk Dette utstyret er i samsvar med de grunnleggende krav og andre releva...

Страница 21: ...the equipment In order to fulfil the certification requirements the OEM must comply with FCC regulations 1 The system integrator must ensure that the text on the external label provided with this dev...

Страница 22: ...ollowing form If the CE marking is reduced or enlarged the proportions given in the above graduated drawing must be respected The CE marking must have a height of at least 5mm except where this is not...

Страница 23: ...Range to which this declaration relates are in conformity with the appropriate standard EN 300 328 following the provisions of the Radio and Telecommunications Terminal Equipment Directive 1999 5 EC F...

Страница 24: ...sary to return the product to Mantracourt please include a note stating name company address phone number and a detailed description of the problem Also please indicate if it is a warranty repair The...

Отзывы: