Mantracourt Electronics Limited
T24-PR1 User Manual
12
Output Settings
Here you can change various settings that influence the output from the module.
Items you can change:
Duplicate
Whether to produce the same output twice each time an output is triggered.
Useful, for example, with a printed output where a customer requires a
receipt.
Min Interval
Minimum time allowed between triggered outputs entered in milliseconds.
Triggers arriving within this time since the previous trigger will be ignored.
Example: You may want to limit printouts to once every 10 seconds. By setting
the Min Interval to 10000 the printouts would be limited to once every 10
seconds even though the printouts were requested at a much faster rate.
Gross Text
Enter text to replace the <GN> token with when the device is in gross mode.
Net Text
Enter text to replace the <GN> token with when the device is in net mode.
Print On Error
Whether to trigger an output when any input device fails to deliver new data
within the timeout period.
Example: Data arrives every 5 minutes which is used as input 1 (<V1>). This
same data tag is used to trigger a printout. Normally if the data fails to arrive
the printout would not get triggered. By setting this property a printout would
be triggered when the data failed to arrive (Within the timeout period for that
input) and the values would show ------- instead of the numeric value when
<V1> is decoded. This would indicate to the user that there is a problem.
Log Number
Enter a log number that is used when the <LOG> token is decoded. Each time
an output is triggered this log number is incremented. This number will wrap
to zero once it reaches the maximum value displayable due to the Log Digits.