Mantracourt Electronics Limited
T24-ACMm & T24-BB1 User Manual
2
Introduction / Overview
The T24-ACMm provides a convenient way to connect to one of the range of T24 acquisition modules. The T24-
ACMm also includes an LED for indicating when the device is transmitting.
The T24-BB1 provides 3V DC power to the T24-ACMm via a pair of ‘AAA’ cells.
Connecting an input to the acquisition module is also made easier by utilising 2 part screw terminals.
Getting Started
The T24-ACMm requires that the acquisition module is factory fitted therefore this requires specifying at the
time of ordering.
Opening the Case
The case lid is secured with 2 x Philips head screws, remove the screws and the case will come apart.
Connecting Power
Power is supplied by fitting 2 X ‘AAA’ cell 1.5 Volt batteries as directed inside the T24-BB1
Note there is no reverse polarity protection on the T24-BB1.
LED Indicator
The T24-ACMm is fitted with an LED to provide a visual indication of data transmission from the acquisition
module inside. The LED flashes when a data transmission occurs.
+
+
Remove these two screws