Troubleshooting
Fault occurrence
Cause
Rectification
Atomiser disc not rotating
Atomiser contaminated
Thoroughly clean atomiser, remove plant parts
as necessary
Battery empty
Charge battery
Fuse blown
Replace fuse on powerpack
(Replacement fuses are located in the
powerpack housing)
No electrical contact
Check cable or connector contact
Battery defective
Install new battery
Atomiser motor defective
Install new motor
Connect the brown cable to Plus (+).
Atomiser spray one-sided
Rotation disc turning in the wrong direction Connect cable correctly!
Selectively plug the brown cable onto the
contact pin on the switch/valve unit.
Connect the blue cable via the round pin plug.
Check to ensure the battery connection to the
powerpack is correctly poled,
blue cable to Plus (+).
Atomiser spray too wide
Width adjustment improperly set
Loosen screws (F, see page 3) and correctly
adjust the left or right width settings.
Atomiser drips
Metering valve incorrectly set
Check setting, see table
Atomiser disc defective / contaminated
Replace / clean disc
Atomiser spray discharge contaminated
Clean
Atomiser foams
Residual water in system
Completely empty container, hose, segmental
atomiser.
Air in hose line
Hose connection
Shorten the hose slightly and set onto the hose
nipple.
/ Filter leaking
Re-tighten the screw on the filter.
Clamping bush fixing screw
Metering pump does not draw
Pump carrier
Metering pump
Metering pump does not draw
1. Loosen fixing screw
2. Pull out metering pump 1-2 mm
3. Tighten fixing screw