Manson Engineering Industrial SBC-7100 Series Скачать руководство пользователя страница 2

Precautions

1.

Before   using   the   charge/load   controller,   read   all   the   instructions   and   cautionary   markings   on   the
charge/load controller, the batteries and the photovoltaic panels.

2.

Do not attempt to repair the controller. Incorrect re-assembly may result in a risk of electric shock or
fire.

3.

To reduce risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning.
Turning off controls will not reduce this risk. PV panels produce power when exposed to light – cover
them with opaque material before servicing.

4.

Working in Vicinity of a Lead Acid Battery is dangerous. Batteries generate EXPLOSIVE gases during
normal operation. Provide ventilation to outdoors from the highest point of the battery compartment.

5.

This charge/load controller is intended to be used with a battery supply of 12 VDC nominal voltage.

6.

Be extra cautious to reduce the possibility of dropping a metal tool onto batteries. It might spark or
short-circuit batteries or other electrical parts that may cause explosion. Cover wrench handles with
plastic tape or vinyl dip coating material.

Specifications

SBC-7100 Series

Models

7108

7112

7120

Battery voltage

12V

Maximum PV panel open circuit voltage

26V

Continuous load/charge current 

8A

12A

20A

Maximum charge current (5 mins)

10A

15A

25A

Maximum load current (5 mins)

10A

20A

25A

Operation current(no Load and no PV)

30mA

Voltage across terminals (PV to Battery)

0.6V

0.6V

0.8V

Voltage across terminals (Battery to Load)

0.3V

0.3V

0.4V

Electronic Blocking

(To protect against reverse polarity connection of PV panel and to block
current from battery to PV panel when voltage of battery is higher than PV
panel)

Yes

Battery reverse polarity protection

Yes

Overcharge & Over-discharge protection

Yes

Battery status LED indication

5-State LED Indications

Charging status indication

3-State LCD Display

Recommended wire size

#12AWG

#10AWG

Weight

0.47kg

Dimension (WxDxH)

150 x 85 x 45 mm

Fuse

15A

20A

30A

Operating ambient temperature

-10 to 50 °C

Over temperature protection

Yes

Battery charging float voltage setting

Adjustable from 12.0-16.5V

Battery charging bulk voltage setting

Adjustable from 12.0-16.5V

DC load control mode (For DC load terminal):

    Low Voltage Disconnect(LVD)

Adjustable from 8-16V

    Low Voltage Reconnect(LVR)

Adjustable from 8-16V

P.1

Содержание SBC-7100 Series

Страница 1: ...PV Charge Controller Settings 4 3 4 2 Select the Auto Manual Equalization charging and Night Light Mode 6 4 PV Charge Control Mode 6 4 1 3 Stage Charge Control 6 4 2 Equalization Charging Mode Automa...

Страница 2: ...plastic tape or vinyl dip coating material Specifications SBC 7100 Series Models 7108 7112 7120 Battery voltage 12V Maximum PV panel open circuit voltage 26V Continuous load charge current 8A 12A 20A...

Страница 3: ...Adjustable Low Voltage Disconnect and Low Voltage Reconnect Build In Microprocessor for PV charge control to maximize the charging efficiency Overcharge and Over discharge Protection Over Temperature...

Страница 4: ...rge Controller should be installed in a dry sheltered location away from sources of high temperature and moisture 3 2 LED Indicator Red Flashing Battery Voltage is lower than 12 6V Constant Red Batter...

Страница 5: ...the total Ampere Hour input to the system in current day L1D PV_AH Shows the total Ampere Hour input to the system a day before L2D PV_AH Shows the total Ampere Hour input to the system 2 days before...

Страница 6: ...rer s specific recommended values How to adjust the Bulk Float Charge Voltage LVD LVR and Night Light Mode 1 First take out all the connections to the PV controller except those to battery 2 Push up t...

Страница 7: ...ation Eq charging is only for wet type Lead Acid Battery When Auto Equalization Charging is set at ON mode Equalization charge will occur for 2 hours once every thirty days Use the dip switch to selec...

Страница 8: ...olt age Setting for one full hour with various rapid On Off pulses PWM It then switches to Float Charge Mode c FLOAT CHARGE The controller will maintain the battery voltage at the float voltage settin...

Страница 9: ...ce and the controller will return to the charging mode before the Equalization charge 4 3 12V DC Load Terminal Control Mode The 12V DC load terminal is designed for low power DC load such as street li...

Страница 10: ...in Z hours before sunrise Dusk to Dawn Load is turned on all night Measure Night Length The load timer options that turn the load on again before sunrise require that the PV charge controller to measu...

Страница 11: ...rotection The operation temperature of the transistors of the PV Charge Controller is also continuously monitored If excessive temperature is detected the charge controller transistors will repeatedly...

Страница 12: ...the battery status Red LED See Section 3 2 Pin 8 4 Shows the battery status Green LED See Section 3 2 Table 7 Pins configuration Note Pin 3 and 5 are not used in Remote signal Terminal Rev 6 02 2012 7...