Manson Engineering Industrial SBC-2215 Скачать руководство пользователя страница 5

G. Power Supply / 2 Stage Charger  Mode (see Fig.4)

At this mode the Charger On (5) LED becomes red color and only Bulk and Float LED will function. The bulk LED will be off
when battery is charged to about 80% full.
The 3 stage charger becomes a 2 stage charger or as power supply in this selected mode because 3 stage charger overcharges
battery with external load.
This selected mode is intended for use to charge battery with external load such as caravan or other  battery and external load
combination.
A 2-Stage charger can be used as a combination charger/power supply. An external load can draw current from the charger while
the charger is recharging a battery. The charger doesn't care how much current is being diverted by an external circuit as it
switches from Bulk mode (constant current ) to Float mode based only on the battery terminal voltage.
However, a 2-Stage charger cannot completely charge the battery when the charger switches from bulk mode to float mode. After
switching to float mode, the battery will, in most cases, be about 80% recharged. The battery receives the remaining recharge
while in float mode over several days.
It is highly recommended to switch back to the 3 Stage Charger Mode periodically when the external load is disconnected.
Also the external load should not be more than 50% of the max. current of the charger , unless the battery is fully charged up . If
the bulk LED is on most of the time then the load is too large.

G1. As a stand alone power supply

It can also be used as a stand alone power supply without connection to a battery 
It will provide a constant voltage according to the selected Float Voltage (26.4/27.0/27.6V) and rated DC current of the charger.
However, it is not recommended for high surge load (such as lamp) in stand alone application as the initial high surge current
will trigger the overload protection of the power supply.

Fig.4  Power Supply / 2 Stage Charger Mode Application

Содержание SBC-2215

Страница 1: ...er serviceable parts inside Do not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective...

Страница 2: ...2 Battery Type Selection Slide Switch to set charger for AGM Gel Wet and Calcium Calcium type battery 3 Float Voltage Selection Slide Switch to set Float Charge voltage to 26 4 27 0V 27 6V 4 Charge S...

Страница 3: ...nstallation and Connection Observe the warnings safety precautions before rushing to install and operate the charger Check battery condition fill up cells for wet battery clean battery poles Secure th...

Страница 4: ...of current necessary for maintaining the capacity The float voltage is preset independently by user according to the type of battery such that battery can be connected permanently to the charger when...

Страница 5: ...Stage charger cannot completely charge the battery when the charger switches from bulk mode to float mode After switching to float mode the battery will in most cases be about 80 recharged The battery...

Страница 6: ...charger to activate the temperature control function never plug in the charger during charging I Cable Size Selection Wire Size AWG Area mm2 Maximum one way distance feet for 2 Voltage loss 24V 15A M...

Страница 7: ...ours charging time Absorption light remains on all the time Wrong battery type selection eg charge gel battery with Calcium Calcium OR Wet type selection Total battery capacity is too high for dual ch...

Страница 8: ...3 2A 9 3 3 9A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed S...

Отзывы: