Manson Engineering Industrial SBC-2215 Скачать руководство пользователя страница 3

10. Power Switch 

To turn on and off AC power to Charger.

11. Inlet AC Socket with Fuse Holder

B.  Battery Type Selection

AGM/GEL

: Sealed type (VRLA) , AGM-GEL , Maintenance Free , Automotive or Deep Cycle lead acid batteries

WET

: Flooded Type lead acid batteries (to which water can be added) Automotive or Deep Cycle 

Calcium-Calcium : Sealed type (VRLA) Lead Acid batteries with Calcium content Automotive or Deep Cycle 

B1. FLOAT VOLTAGE SELECTION

These fine tuned selections of float voltages enable the best voltage level for maximum battery life. Choose 27.6V when in doubt
or in Power Supply Mode.
Follow the markings on Deep Cycle batteries of the Standby float voltage.

B2.   Recommended  Battery Capacity 

The following minimum AH capacities are  a generalized suggestion, some batteries can take higher charge current, check with
battery manufacturers for charging batteries with smaller capacity. 

Charger Model

SBC-2215 , 15A

SBC-2220 , 20A

SBC-2225 , 25A 

Battery Capacity

50 AH - 150 AH 

70 AH - 200 AH

80 AH - 250 AH 

C. Battery Charger Installation and Connection

Observe the warnings & safety precautions before rushing to install and operate the charger.
Check battery condition, fill up cells for wet battery, clean battery poles.
Secure the battery charger in a well ventilated place, make sure the mounting surface is flat and without soft covering material or
loose paper sheet. The air intake is at the bottom and air outlet at the back. Make sure both intake and outlet are not blocked.
Never place charger on top of battery.
Plug in the AC mains and turn on Power Switch , the Charger On LED and the Float LED should be on green indicating Charger is
in good order for charging lead acid battery.
Before connecting or disconnecting the charging cable, turn off the Power Switch and unplug AC cord  from the mains.
First connect the Red cable to Po terminal of charger and the battery Po Pole. Then connect the Black cable to the
Negative – terminal and the Negative – Pole of the battery.
Make sure all the connections are secured and well tighten up, double check on the correct polarity.
Double check again for correct selection of Slide Switch 1 at Charger Mode, Switch 2 for Battery type and  Switch 3 for Float
Voltage setting value.

Fig.2

Содержание SBC-2215

Страница 1: ...er serviceable parts inside Do not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective...

Страница 2: ...2 Battery Type Selection Slide Switch to set charger for AGM Gel Wet and Calcium Calcium type battery 3 Float Voltage Selection Slide Switch to set Float Charge voltage to 26 4 27 0V 27 6V 4 Charge S...

Страница 3: ...nstallation and Connection Observe the warnings safety precautions before rushing to install and operate the charger Check battery condition fill up cells for wet battery clean battery poles Secure th...

Страница 4: ...of current necessary for maintaining the capacity The float voltage is preset independently by user according to the type of battery such that battery can be connected permanently to the charger when...

Страница 5: ...Stage charger cannot completely charge the battery when the charger switches from bulk mode to float mode After switching to float mode the battery will in most cases be about 80 recharged The battery...

Страница 6: ...charger to activate the temperature control function never plug in the charger during charging I Cable Size Selection Wire Size AWG Area mm2 Maximum one way distance feet for 2 Voltage loss 24V 15A M...

Страница 7: ...ours charging time Absorption light remains on all the time Wrong battery type selection eg charge gel battery with Calcium Calcium OR Wet type selection Total battery capacity is too high for dual ch...

Страница 8: ...3 2A 9 3 3 9A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed S...

Отзывы: