IX. Specification

 

 s  

Models

NEP-6185

NEP-6303

Output Voltage Coverage Range 0.5 – 18V

0.5 - 32V

Output Voltage Control

Rotary Encoder System with Fine & Coarse tuning

Output Current Coverage Range

0 – 5A

0 – 2.8A

Output Current Control

Rotary Encoder System with Fine & Coarse tuning

Voltage Regulation

Ripple & Noise (r.m.s.) Voltage

<6mV

Load Regulation
(0 – 100% Load)

<15mV

Line Regulation (±5%)

<15mV

Setting Accuracy

± (0.2% +0.15) V

Voltage Resolution

0.1V

Current Regulation

Ripple & Noise (r.m.s.) Current

<10mA

Load Regulation
(10 – 90% Rated Voltage)

<30mA

Line Regulation (±5% Variation)

<30mA

Setting Accuracy

± (0.3% +0.02) V

Current Resolution

0.01A

Input Voltage

Input Voltage

230VAC / 50Hz~ (120VAC / 60Hz~ or on request )

No Load Input Current (230VAC) <200mA

Full Load Input Current
(230VAC)

<0.9A

Auxiliary Output

Fixed Output 1 with 500mA

5.0Vdc

Continuous Current

0.5A

Fixed Output 2 with 500mA

12.0Vdc

Continuous Current

0.5A

Factory Preset (Sefault Setting)

Preset 1

Votage = 5.0V

Current = 5.0A

Votage = 5.0V

Current = 2.8A

Preset 2

Votage = 10.0V

Current = 5.0A

Votage = 10.0V

Current = 2.8A

Preset 3

Votage = 15.0V

Current = 5.0A

Votage = 15.0V

Current = 2.8A

Содержание NEP Series

Страница 1: ...NEP SERIES User Manual REV 0 2011 08 7673 6185 0000...

Страница 2: ...nels A FRONT PANEL 1 LCD display Indicates output voltage current presets CC CV status of main auxiliary outputs output On OFF running the Cycled Program and faults 2 Output Voltage Control knob Adjus...

Страница 3: ...to the unit 5 Do not replace the fuse before ceasing the problems use same fuse rating 6 Never touch the power supply when your hand is wet 7 Never remove the metal cover without unplugging of AC main...

Страница 4: ...e Knob then quickly press the Current Knob 1 Press the Voltage Knob and then press the Current Knob Icon 1 is flashing to show ready for setting 2 Adjust Voltage Knob for voltage value and Current Kno...

Страница 5: ...ew settings and Icon 3 will start flashing to indicate Preset 3 is ready for setting 5 Adjust Voltage and Current as before and press Voltage and Current Knobs to confirm Preset 3 new settings 6 All t...

Страница 6: ...cordingly 3 Repeat the above to get to Preset P2 then P3 4 Quick press of Voltage and Current Knobs at P3 will exit from the Preset Mode to normal operation mode N at which has no flashing Presets Ico...

Страница 7: ...oves to the next lot of Timed Presets When the power supply is in cycle operation the cycle icon flashes with the time preset in operation Setting the Timed Presets 1 Push Button 4 to Output OFF posit...

Страница 8: ...d P3 7 To set the number of cycles After t3 of P3 has been set and confirmed the P icon will then appears and ready for setting of number of cycles Adjust the voltage knob to set the number of cycles...

Страница 9: ...ycle Icon is flashing This serves as a warning of wrong setting of 3 preset timers Remarks A If the number of cycle is set at zero then the unit will run infinite cycles B To exit from the Timed Prese...

Страница 10: ...ent user presets 3 Programming of timer and auto cycling of preset in sequence 4 Rotary encoder tuning of V I 5 Output On Off switch with status indication 6 Large LCD display for V I Presets CC CV st...

Страница 11: ...on Ripple Noise r m s Current 10mA Load Regulation 10 90 Rated Voltage 30mA Line Regulation 5 Variation 30mA Setting Accuracy 0 3 0 02 V Current Resolution 0 01A Input Voltage Input Voltage 230VAC 50H...

Страница 12: ...LCD Indications Voltage and Current C C And C V Aux 1 and 2 Status Output ON OFF 3 User Defined V I Presets Running the Cycled Program Fault Indication OVP Over Voltage OCP Over Current or Load OTP Ov...

Отзывы: