Operations and Displays
Installation
Connect shunt according to one of the connect in bidirectional or unidirectional connection diagram.
Then connect DPM-3321 to shunt. The DPM will start up and show information in following
sequence.
Software version
Shunt rating
Sampling time
Normal operation
Set shunt rating of DPM
In case it is need to change the DPM shunt rating to match your shunt, proceed as following:
1. Disconnect phone plug from shunt.
2. Press and hold the reset button. Then reconnect the phone plug to shunt.
3. The LCD displays present shunt setting.
4. Release the reset button.
5. Quick press on the reset button to select the your shunt rating in 50A, 100A or 200A.
6. Press and hold the reset button until the LCD displays Sample time.
7. Unplug and replug the phone jack to check if your new shunt setting has been successful.