Manson Engineering Industrial DPM-3321 Скачать руководство пользователя страница 2

Controls, Indicators & terminals 

 

FRONT 

 

 

 

Shunt connect flat cable with phone plug 

 

LCD Display: 

Constant displays: V, A, and W. 

  Scrolling Displays:  Two sets of values for most parameters, the positive value means current 

 

 

going into the battery and the negative value means current coming out of 

 

 

the battery . 

 

 

Parameters:  Time period in use, Ah (Amp Hour), WH (Watt Hour), 

 

 

 

Vp (max voltage), Ap (max.current), Wp ( max.Watt), 

 

 

 

Vm (min.Voltage), Negative: -Ah, -WH, -AP, -Wp back to 

 

 

 

Time period in use. 

 

 

Freeze Scrolling display:  Hold and release of any scrolling display by 

 

 

 

 

quick press of RESET button

 

SIDE 

 

 

 

Micro USB socket: 

Either for connection to PC for data retrieval & real time monitoring. 

 

   

 

 

Or for connection to External Power source (such as 5V USB Power 

 

   

 

 

Bank) to extend voltage range from 5V-60V to 0V-60V. 

 

Reset Switch:   

To set the data logging interval from 30 sec to 180 sec. 

 

   

 

 

To clear old data. 

 

   

 

 

To freeze and release rolling display 4. 

Содержание DPM-3321

Страница 1: ...battery Current charging going to battery is Positive and current out of battery discharging is Negative The power meter is powered up by 5 60V dc from either side or an external USB power bank for ex...

Страница 2: ...t Hour Vp max voltage Ap max current Wp max Watt Vm min Voltage Negative Ah WH AP Wp back to Time period in use Freeze Scrolling display Hold and release of any scrolling display by quick press of RES...

Страница 3: ...Wiring Diagram Bi directional Connections with 5 60V DC range...

Страница 4: ...al application with external DC for 0 60V meter range Bi directional application connect to PC Remark PC software driver software and Bluetooth manual can be download from http www manson com hk produ...

Страница 5: ...tional Connections When used in unidirectional applications there is no negative current The following are some examples for meter connections Unidirectional application with external DC for 0 60V met...

Страница 6: ...Unidirectional Application Connect to a PC Remark PC software driver software and Bluetooth manual can be download from http www manson com hk product dpm 3321...

Страница 7: ...PM In case it is need to change the DPM shunt rating to match your shunt proceed as following 1 Disconnect phone plug from shunt 2 Press and hold the reset button Then reconnect the phone plug to shun...

Страница 8: ...on to change value in the digit 4 PRESS and HOLD the RESET button to confirm the chosen digit in the number It will show OK then go to set next digit 5 Repeat step 3 and step 4 for all digits 6 After...

Страница 9: ...age over the last screen update interval Vp is the Peak maximum voltage Vm minimum from the source side since start up screen to the present moment There is no negative Vp or Vm registered Charge Amp...

Страница 10: ...can be reset to 0 by using reset button Press and hold the Reset button until the LCD display show Press again 5 seconds to reset Then release the Reset button quickly press again and hold 5 seconds...

Страница 11: ...Discharger Data Log Graph...

Страница 12: ...10 000W Energy Kilo Watt Hour KWH Max recorded KWH 9999 9KWH 999 9KWH Resolution of KWH 0 1KWH Registered Peak Voltage Vp Min Voltage Vm Peak Current Ap Negative Peak Current Ap The new high and low v...