DESCRIPTION 

 

The 100mm fan is an axial extraction fan suitable for domestic bathrooms and W.C’s. The 150mm fan is an 
axial  extraction  fan  suitable  for  domestic  kitchens  and  utility  rooms.  They  are  available  as  wall  or  panel 
mounted models with shutter timer and humidity combinations. 

Complies with the requirements of European Directives 2006/95/EC (LVD), 89/336/EEC (EMC) 

FAN LOCATION 

 

A short circuit of the airflow should always be avoided, Fig.1. by siting the fan as far away as possible from, 
and opposite to the main source of, air replacement in the room

FITTING INSTRUCTIONS

 

A. 

PANEL MODEL

 

1. 

This model should be installed into a closed duct system of at least 1.2m long or protected by an 
exterior air grille that must comply with the standard requirements of your country to prevent access 
to the fans impeller. 

2.   

Either cut a 105mm diameter hole for 100mm fans or a 155mm diameter hole for 140mm fans. 

3. 

Loosen  the screw at  the bottom of the grille and remove the front  grille.   Mark the  screw  centres 
through the holes in the fan back plate. Drill, plug and screw into position. 

4. 

After installation, ensure impeller rotates freely and the shutters can open. 

B.   

WALL MODEL 

1.   

Either  cut  a  115mm  diameter  hole  for  100mm  fans  or  a  170mm  diameter  hole  for  150mm  fans, 
through the wall and insert the wall sleeve. Slope the sleeve slightly downwards away from the fan. 
Cut to length and cement both ends into position flush with the wall faces.  

2. 

Loosen  the  screw  in  the  bottom  of  the  grille  and  remove  the  front  grille.  Mark  the  screw  centres 
through  the  holes  in  the  fan  back  plate.  Drill,  plug  and  screw  into  position.  Fix  exterior  grille  into 
position  with  the  louvres  positioned  downwards  (Note:-  The  grille  must  comply  with  the  standard 
requirements  of  your  country  to  prevent  access  to  the  fans  impeller.  The  wall  kit  used  in  this 
installation  should  provide  a  minimum  ducting  length  of  160mm  from  the  fans  back  plate  to  the 
inside of the external grille).  

3.   

After installation, ensure impeller rotates freely and the shutters can open. 

 

 

WIRING INSTRUCTIONS 

 

WARNING:  ENSURE  THAT  THE  MAINS  SUPPLY  IS  SWITCHED  OFF  BEFORE  MAKING 
ELECTRICAL CONNECTIONS. 

The extraction fan is suitable for connection to 220-240V 50Hz supply. It is a class ll double insulated product and 

MUST NOT 

be earthed. 

The cross - sectional area of supply cord used should be ranged from 1 - 1.5mm

2

 

Cable entry can only be made from the rear of the fan.  

Electrical connections depend upon the type of fan being installed and the required mode of operation. After wiring 
is complete replace the grille, turn on mains supply and check operation. 

A.  BASIC FAN / SHUTTERED FAN TYPE 

Single speed fan. Controlled by remote switch (e.g. light switch or auto sensor) Fig.2. 

B.  TIMER / SHUTTERED TIMER TYPE 

Single speed with overrun timer. The fan must be wired to a lighting circuit switch. Fig.3. 

When switched ‘ON’, the fan will operate at full speed and will continue to run for a pre-set time after the switch is 
turned ‘OFF’. 

 

 

Содержание SLIM F100

Страница 1: ...0 16 IP44 F100TS 1 2 3 220 240 50 16 IP44 F100HS 1 2 3 220 240 50 16 IP44 F150 1 2 3 220 240 50 16 IPX4 F150S 1 2 3 220 240 50 16 IPX4 F150T 1 2 3 220 240 50 16 IPX4 F150TS 1 2 3 220 240 50 16 IPX4 F150HS 1 2 3 220 240 50 16 IPX4 H models Humidity Adjustment I To activate the timer function remove jumper JP1 If fitted Once removed the fan will run on for a fixed period of approx 15 mins T models T...

Страница 2: ...F The fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time G Where ducted fans are used to handle moisture laden air a condensation trap should be fitted Horizontal ducts should be arranged to slope slightly downwards away from the fan H This appliance is not intended for use by persons including children with reduced physical sensory or menta...

Страница 3: ...nd cement both ends into position flush with the wall faces 2 Loosen the screw in the bottom of the grille and remove the front grille Mark the screw centres through the holes in the fan back plate Drill plug and screw into position Fix exterior grille into position with the louvres positioned downwards Note The grille must comply with the standard requirements of your country to prevent access to...

Страница 4: ... the fan a fixed over run time of approx 15 mins HUMIDITY SET POINT ADJUSTMENT BEFORE ADJUSTING THE CONTROLLER SWITCH OFF THE MAINS SUPPLY HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION 1 Remove the fan grille The controller is factory set to switch on at about 70 RH The humidity set point can be adjusted from 65 95 RH by altering the adjuster on the control PCB 2 To LOWER the se...

Отзывы: