Installation and Wiring Instructions for the Quiet Fan Conceal Range

 

 

IMPORTANT: 

READ THESE INSTRUCTIONS BEFORE COMMENCING THE 

INSTALLATION

 

DO NOT install this product in areas where the following may be present or occur: 

  Excessive oil or a grease laden atmosphere. 

  Corrosive or flammable gases, liquids or vapours. 

• 

Ambient temperatures higher than 40°C or less than –5°C. 

• 

Possible obstructions which would hinder the access or removal of the Fan. 

 

SAFETY AND GUIDANCE NOTES 

 

A. 

All wiring to be in accordance with the current I.E.E. Regulations, 
or the appropriate standards of your country and 

MUST 

be 

installed by a suitably qualified person. 

B. 

The Fan is suitable for installation within Zones 1 & 2. 

C. 

The Fan should be provided with a local isolator switch capable of 
disconnecting all poles, having a contact separation of at least 
3mm. 

D. 

Ensure that the mains supply (Voltage, Frequency, and Phase) 
complies with the rating label. 

E. 

The Fan should only be used in conjunction with the appropriate 
Manrose products. 

F. 

The Fan should only be used in conjunction with fixed wiring. 

G. 

When the Fan is used to remove air from a room containing a fuel-
burning appliance, ensure that the air replacement is adequate for 
both the fan and the fuel-burning appliance. 

H. 

The Fan should not be used where it is liable to be subject to direct 

water spray for prolonged periods of time. 

I. 

Where ducted Fans are used to handle moisture-laden air, a 
condensation trap should be fitted. Horizontal ducts should be 
arranged to slope slightly downwards away from the Fan. 

J. 

This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 

K. 

Children should be supervised to ensure that they do not play with 
the appliance.  

Содержание Quiet Fan Conceal X5 S

Страница 1: ...Manrose Quiet Fan Conceal X5 T QF100HTX5CON Manrose Quiet Fan Conceal X5 HT PLEASE READ THESE INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Installation and Wiring...

Страница 2: ...upply Voltage Frequency and Phase complies with the rating label E The Fan should only be used in conjunction with the appropriate Manrose products F The Fan should only be used in conjunction with fi...

Страница 3: ...f the fan and pull the grille away from the chassis 4 Mark the screw centres through the holes in the fan back plate Drill plug and screw into position 5 After installation ensure impeller rotates fre...

Страница 4: ...AN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION OR MAINTENANCE See Fig 1 2 3 4 5 6 QF100SX5CON Single speed fan Controlled by remote switch e g light...

Страница 5: ...installation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life...

Страница 6: ...4 clips as shown below 2 To Refit the cover line up the 4 clips on the rear of the cover and gently push until you hear a Click 3 Fig 3 QF100TX5CON QF100HTX5CON Fig 5 QF100TX5CON Timer Adjustment To R...

Страница 7: ...djustment Humidity Adjustment To INCREASE SET POINT turn the adjuster CLOCKWISE This makes the controller LESS sensitive To REDUCE SET POINT turn the adjuster ANTI CLOCKWISE This makes the controller...

Страница 8: ...eading RG6 1AZ EU Authorised Representative Manrose Bedrijvenweg 17 7442 CX Nijverdal Nederland authorisedrep manrose nl 496954 A 0621 Contact Information Website www manrose co uk email sales manrose...

Отзывы: