CEILING INSTALLATION
Fig. 5
1.Find a suitable location and cut the appropriate size (150mm) diameter. Ensure there are no
cables or pipes above the ceiling when cutting.
2.Remove the front panel of the exhaust fan and position against the ceiling mounting surface
and mark the four fixing screw points and cable entry, and then drill to suit.
3.Place the exhaust fan through the cut out hole and position the exhaust fan in place.
4.Connect the Live and Neutral supply wiring to the terminal block, and replace the terminal
block cover via the screw.
5.Secure the fan to the wall via the four screw and mounting holes, or via the 2 quick-fits, which
are located on the sides of the exhaust fan. (See Fig. 6)
6.Replace the front panel.
Note:
Where ducting (not included) is used, ensure the outlet ducted in such that to avoid the
back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.
5. Secure the fan to the ceiling via the four screws and mounting holes, and / or via the 2
quick fit tabs, which are located on the sides of the exhaust fan spigot. (See Fig. 6)
6. Replace the Front panel.
Four mounting
screw holes
INSTALLATION DIAGRAMS
Remove plastic cover to access the quick-fits clip screw.
(Right)
Turn screw clock-wise to make the metal clip come out to the
side and lock into place against the side of the ceiling. (Above)
SPECIFICATION
Model
VUF150WH
Rated voltage
(V/Hz)
Input
(W)
Air-Flow
(m³/h)
Noise
(dB)
Size
(mm)
25
210
39
150
Fig. 6
220-240V~50Hz
MAINTENANCE & SERVICE
Before carrying out any maintenance, ensure the power is switched OFF from the mains power
supply.
1.Wipe down the fascia and grilles with a wet soapy cloth only. Do not allow water to contact
electrical part, such as motor.
2.Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating
fan.
3.Do not immerse resin parts into hot water over 60°C.
4.Do not place hot objects near or install nearby hot appliances.