4 Installation options
The fan can be installed in any of three ways
depending on the desired function, as detailed below:
1 Humidity control only, see diagram 1
The fan is connected to constant phase (L) and
neutral (N) for automatic humidity control.
The timer can be activated manually by installing a pull
cord and pulling it (see page 8).
2 Humidity c timer with light switch, see
diagram 2
The fan is connected to constant phase (L) and
neutral (N) for automatic humidity control.
Switched live (SL) is connected to activate the fan's
timer, i.e. when the bathroom light is switched on. This
option provides a 90-second start delay.
3 Humidity c timer with retractive switch, see
diagram 3
The fan is connected to constant phase (L) and
neutral (N) for automatic humidity control.
Switched live (SL) is connected to activate the fan's timer
using a retractive switch.
This option gives direct start-up of the fan.
Wiring diagram
1
2
3
SL N L
SL N L
SL N L
L
N
L
N
L
N
TIMER
HUMIDITY
TIMER
CONSTANT
5
15
30
SPEED
SILENT
MAX
S
MIN
1
2
3
SL N L
SL N L
SL N L
L
N
L
N
L
N
TIMER
HUMIDITY
TIMER
CONSTANT
5
15
30
SPEED
SILENT
MAX
S
MIN
7