Installation Instructions

 

Specifications are subject to change without notice  

Page 6

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

 

Inline Extraction Fan Kit - 125mm Standard Profile

Timer Adjustment only

This time delay can be adjusted by firstly switching off the power to the fan and removing the cover on the bracket. Locate the rotary adjuster as 
shown in (Fig 4). The serrated adjuster wheel can be rotated using a thumbnail to adjust the timer setting. 
 
+  =  Rotate to the right to increase the time (indicated by + on the diagram) 
-   =  Rotate to the left to decrease the time  (indicated by -  on the diagram) 

 

Only adjust with power switched off.

 

All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm

2

 in 

section. All wiring must comply with current regulations. This system should be installed by a registered electrician. These units 
are double insulated and therefore do not require an earth. 

INSTALLATION

PUB0330 2208

Flexible duct

Internal diffuser

External grille

The inline extraction fan 
screwed to the joist

TYPICAL INSTALLATION

Recommended

mounting position

Содержание FAN5371

Страница 1: ...lation within a shower cubicle The high performance fan provides high levels of extraction and enables additional ducting to be added to this system DIMENSIONS SPECIFICATIONS Duct mm Fan Type Max Fan...

Страница 2: ...for ventilation The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventila...

Страница 3: ...d exclusively by the manufacturer or by an appointed representative Failure to comply with the above may endanger the safety of people and cause possible damage to the whole system The fan kit is to b...

Страница 4: ...AC Switch Switched Live 12VAC Extract a Lite 12VAC light FAN Existing Light 230VAC Existing Switch 12VAC Permanent Live Timer Model Standard Model 3 PERMANENT LIVE 2 SWITCHED LIVE 1 NEUTRAL 3 2 1 Neut...

Страница 5: ...ternal grille select a suitable position either in the soffit or on an outside wall and cut a 130mm hole Attach one end of the flexible duct to the grille and from the outside feed the ducting through...

Страница 6: ...djust the timer setting Rotate to the right to increase the time indicated by on the diagram Rotate to the left to decrease the time indicated by on the diagram Only adjust with power switched off All...

Страница 7: ...on To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever b damage to consumable items...

Отзывы: