background image

Installation Instructions

Specifi cations are subject to change without notice  

Page 1

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

Inline Extraction Fan Kits - 150mm Std Profi le

Thank you for purchasing this quality 150mm inline extraction fan kit.

To ensure correct function and safety, please read all instructions before using the product and keep all instructions for future reference. 

Description

Order Code

with LED

Standard Switching

FAN5369

Timer

FAN5370

with Halogen Light

Standard Switching

FAN0803

Timer

FAN0804

When using electrical appliances, basic safety precautions should always 
be followed to reduce the risk of fi re, electrical shock and personal injury.

This Manrose inline extraction fan kit is designed for ventilation within a shower 
cubicle. The high performance fan provides high levels of extraction and enables 
additional ducting to be added to this system. 

A

B

C

D

E

F

G

200

143

170

185

200

80

148

DIMENSIONS

A

C

B

D

SPECIFICATIONS

Duct

(mm)

Fan Type

Max.

Fan Watts

(W)

Max.

Fan Pressure

(PA)

Free Air Fan Performance

Specific

Fan Power

(W/l/s)

Interior Grille

Exterior Grille

(l/s)

(m

3

/hr)

150

EC Axial

18

91

105

380

0.17

Round White

and

Square White

Weatherproof Cowl White

and

Fixed Louvre White

Note:

Grille cut-out size is a nominal diameter for a circular cut-out.

TECHNICAL

Fan Kit Type

Supply

Output

Wattage

Beam 
Angle

Total 

Wattage

Motor Housing

Impeller & 

Outer Rotor

Ducting

with LED

220-240V AC, 50Hz

Driver

12V DC

12V 3W

25º

21W

Die cast aluminium

PBT plastic

5m Flexible PVC

with Halogen Lamp

220-240V AC, 50Hz

Transformer

12V AC

12V 50W

60º

68W

Die cast aluminium

PBT plastic

5m Flexible PVC

F

E

G

Diffuser

Fan

Compliance: AS/NZS60335-2.80:2016

FAN TIMER SELECTION

Please use the FAN2444 fan timer model shown 

Do not use old model FAN2444 (with resistor) or FAN0372 fan timers

Содержание FAN5369

Страница 1: ...provides high levels of extraction and enables additional ducting to be added to this system A B C D E F G 200 143 170 185 200 80 148 DIMENSIONS A C B D SPECIFICATIONS Duct mm Fan Type Max Fan Watts...

Страница 2: ...for ventilation The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventil...

Страница 3: ...se of damage to the supply cord switch off the device and do not tamper with it Damaged supply cords must only be repaired or replaced exclusively by the manufacturer or by an appointed representative...

Страница 4: ...LIVE NEUTRAL EARTH LIGHT SWITCH FLUSH BOX WALL MOUNTED BLUE BROWN GREEN YELLOW S L Diagram 1 Diagram 3 Diagram 2 230V AC 12V AC SELV transformer OR 230V AC 12V DC LED Driver Existing Light 230V AC Ex...

Страница 5: ...ed independent of the extraction fan installed Diagram 1 Recommended transformer FAN6696 Recommended lamp FAN0431 5 Place the white ceiling cover onto the inline extraction fan kit chassis by position...

Страница 6: ...to a person using either the shower or the bath Wiring of Timer Switching Models FAN5370 and FAN0804 Diagram 3 The fan can be connected to the light switch so that the fan will start when the light i...

Страница 7: ...ributed by Simx Limited Inline Extraction Fan Kits 150mm Std Profile Flexible duct Internal grille External grille Inline extraction fan screwed to the joist TYPICAL INSTALLATION PUB01547 2001 Recomme...

Страница 8: ...for a consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever b damage to consumable items such as lamps and starters and c damage arising from...

Отзывы: