Diagram 1

IMPORTANT

FAN MUST BE 
INSTALLED THIS 
WAY UP WHEN 
MOUNTED ON WALL

 Specifi 

cations: 

 

Model:  

NZNVF120SBB; NZNVF120TBB

 Electrical: 

 

220-240V~50Hz

 

Fan Wattage:  

25W

 

Max Temp:  

40˚C     

 

Airfl ow:  

36l/s (130m3/hr)

 

Max Pressure:  

35 Pa

 

Sound Volume:   41 dB(A)

 

IP Rated:  

IP44 (except pullcord model IP24)

Diagram 1A

8.

 

Wiring of Pullcord Models XF125P and XP125P (see Diagram 1).

 

(This model is unsuitable for ceiling mounting).

This fan has its own integral pullcord on/off switch. The fan should not be accessible to a 
person using either the shower or the bath.

  

NOTE:

 

All wiring must be fi xed securely and the cable to the fan should be a minimum  

of 1mm

2

 in section. All wiring must comply with current Regulations. This system should 

be installed by a qualifi ed electrician.

9. 

Wiring of Timer Model XF120T and XP120T
See Diagram 2 & 2A.

 

The  fan can be connected to the light switch so that the fan will start when the light is 
switched on.  When the light switch or pullcord is switched off the fan will run for between 
20 sec & 30 minutes  (pre-set to 1 minute). The fan should not be accessible to a person 
using either the shower or the bath.

Timer Adjustment XF120T & XP120T only.

 

This time delay can be adjusted by fi rstly switching off the power to the fan and removing the  

 

fascia.  Locate the rotary adjuster as shown in

 

Diagram 2. 

The serrated adjuster wheel  

 

can be rotated using a thumbnail to adjust the timer setting.  

      

+  =  Rotate to the right to increase the time (indicated by + on the diagram)

      

-   =  Rotate to the left to decrease the time (indicated by - on the diagram)

 

Only adjust with power switched off.

 NOTE:

 

All wiring must be fi xed securely and the cable to the fan should be a minimum of 

1mm

2

 in section. All wiring must comply with current Regulations. This system should be 

installed by a qualifi ed electrician.

            For timer adjustment see diagram 2B min 30 secs, max 30 mins.

 • 

 

 

Isolate the mains supply before making any electrical connections. This system should be    

 

 installed by a qualifi ed electrician.

  

• 

 Fan should only be installed by fi xed wiring, a fl exible cord should not be used.

• 

 The appliance is not intended for use by young children or infi rm persons without supervision.

• 

 Young children should be supervised to ensure that they do not play with the appliance.

• 

 Precautions must be taken to avoid the back-fl ow of gases into the room from    

  

  

 the open fl ue of gas or other open-fi re appliances when mounted in outside windows or walls.

IMPORTANT  