MANN+HUMMEL TRIDIM Tri-Lock GS Скачать руководство пользователя страница 7

TRI-LOCK OPERATION AND MAINTENANCE

TRI-DIM

7

Start-Up Procedures

 

Getting Started

BEFORE YOU START

  The system must be shutdown prior to any filter installation or 

removal. Air flow should be stopped or a bypass of the air system 
must be made.

  Consult with the safety officer and perform a job safety 

analysis prior to installing or removing any filter(s). Make sure 
all personnel are wearing the required personal protective 
equipment (PPE).

START-UP PROCEDURE

1.  

Clean outside the door, work area and all metal surfaces.

2.  

Provide filter: Provide a new HEPA filter(s) and or prefilter for 
each tier.

3.  

Remove door: Loosen all doorknobs on the section where the 
filter(s) are to be removed. Lift the door off the door studs and 
swing open on the hinge.

*Option - lift the door off the hinge and place in a safe location.

4. 

Unseal the filter: Pull the arm all the way outward to the open 

position. The mechanism will pull the filters from the gel track 
via extractor clips on the filters. This allows the filter to release 
from the knife-edge.

For a gasket seal housing, unlock the filter by turning both bolt-
locking mechanisms counterclockwise with a ratchet. This will 
release the filter from the flat edge.

*If there are multiple filters per tier, steps 2-4 should be repeated 
until all filters are removed.

5.

 Remove the dirty filter(s) and dispose in accordance with all 

applicable state and federal laws.

6.

 Slide the new filter(s) into the housing and engage the locking 

mechanism to seal off the filter(s) on the knife edge(s).

7.

 Close the swing bar and latch for a gel-seal filter, or screw down 

the drive bolts clockwise on a gasket-seal filter.

8.

 Replace the door and tighten all the door latches.

Содержание TRIDIM Tri-Lock GS

Страница 1: ...Tri Lock GS FS Operation Maintenance Manual...

Страница 2: ...TION AND MAINTENANCE Tri Lock Operation Maintenance CONTENTS Introduction 3 Application 3 Performance 4 Handling and Storage of Filter Elements 6 Installation of New Housings 6 Start Up Procedures 7 A...

Страница 3: ...nnel and no extrusion Hat sections are located on the top bottom and back of the unit for structural support Each housing is custom manufactured to meet specific end user requirements The unit is cons...

Страница 4: ...echanism guides and secures the filter into the knife edge penetrating the gel and forming a positive seal on the filter face DESCRIPTION OF FLUID SEAL FILTER LOCKING SYSTEM The fluid seal Tri Lock FS...

Страница 5: ...or each filter element apply consistent pressure to maintain the filter seal The applied force has a minimum clamping load of 1 400 pounds per perimeter of the filter The gasket on the filter is compr...

Страница 6: ...r than 0 F or higher than 100 F Stacking of filters is not recommended Movement of filters should be restricted to reduce the chance of damage to the media Any additional filter manufacturer s instruc...

Страница 7: ...e Option lift the door off the hinge and place in a safe location 4 Unseal the filter Pull the arm all the way outward to the open position The mechanism will pull the filters from the gel track via e...

Страница 8: ...eal Method 1 Using the ratchet with a socket remove the two hex nuts and washers for both the top and bottom locking trays 2 Then switch to a socket and remove the hex nut and washers from the linkage...

Отзывы: