MAINS CONNECTIONS

 

Your STEELHEAD RC has been factory set to the correct mains voltage for your country. The voltage setting is 

marked on the serial badge, located on the rear panel. Check that this complies with your local supply.
 
 

Export units for certain markets have a moulded mains plug 

 tted to comply with local requirements. If your unit 

does not have a plug 

 tted the coloured wires should be connected to the appropriate plug terminals in accordance with 

the following code:

GREEN/YELLOW   

EARTH

BLUE 

 

 

NEUTRAL

BROWN 

 

 

LIVE

 

As the colours of the wires in the mains lead may not correspond with the coloured marking identifying the termi-

nals in your plug proceed as follows:

The wire which is coloured GREEN/YELLOW must be connected to the terminal in the plug which is marked 
by the letter E or by the safety earth symbol or coloured GREEN or GREEN and YELLOW.

The wire which is coloured BLUE must be connected to the terminal in the plug which is marked by the letter 
N or coloured BLACK.

The wire which is coloured BROWN must be connected to the terminal in the plug which is marked by the 
letter L or coloured RED.

DO NOT CONNECT/SWITCH ON THE MAINS SUPPLY UNTIL ALL OTHER CONNECTIONS HAVE 
BEEN MADE.

Note: 120 to 240VAC operation changeable with power transformer rewiring 

via internal switch and fuse value change.

100VAC operation changeover achieved via rewiring of power transformer PCB.

100-120V Operation: Uses a 1.5A MDL SLO-BLO fuse.

220-240V Operation: Uses a 0.75A MDL SLO-BLO fuse.

Waste Electrical and Electronic Equipment (WEEE)

Information for customers:
The European Parliament and the Council of the European Union have issued the Waste Electrical and Electronic Equipment Directive. The purpose of the Direc-
tive is the prevention of waste of electrical and electronic equipment, and to promote the reuse and recycling and other forms of recovery of such waste. As such the 
Directive concerns producers, distributors and consumers.

The WEEE directive requires that both manufacturers and end-consumers dispose of electrical and electronic equipment and parts in an environmentally safe man-
ner, and that equipment and waste are reused or recovered for their materials or energy. Electrical and electronic equipment and parts must not be disposed of with 
normal household wastage; all electrical and electronic equipment and parts must be collected and disposed of separately.

Products and equipment which must be collected for reuse, recycling and other forms of recovery are marked with the following pictogram:

Small products may not always be marked with this pictogram in which case this is present in the instructions for use, on the guarantee certi

 cate and printed on the 

packaging.
 
When disposing of electrical and electronic equipment by use of the collection systems available in your country, you protect the environment, human health and 
contribute to the prudent and rational use of natural resources. Collecting electrical and electronic equipment and waste prevents the potential contamination of 
nature with the hazardous substances which may be present in electrical and electronic products and equipment.

Your MANLEY or LANGEVIN retailer will assist with and advise you of the correct way of disposal in your country.

d

i

18

Содержание STEELHEAD RC

Страница 1: ...MANLEY STEELHEAD RC MM MC GRAMOPHONE CARTRIDGE PREAMPLIFIER OWNER S MANUAL MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 USA TEL 1 909 627 4256 FAX 1 909 628 2482 www manley com...

Страница 2: ...NTENTS SECTION PAGE INTRODUCTION 3 INSTALLATION PRECAUTIONS 4 FEATURES AND APPLICATIONS 5 OPERATIONAL NOTES 9 REMORA REMOTE CONTROL OPERATING INSTRUCTIONS 12 TROUBLESHOOTING 16 MAINS CONNECTIONS 18 SP...

Страница 3: ...bility UNPACKING Unpack the preamplifier carefully and make sure that all supplied accessories are present Examine all items for any possibility of shipping damage All six tubes should be standing at...

Страница 4: ...ipment If however the preamp provenance is unknown then the mains voltage selector switch should be checked and reset to the correct voltage if necessary The mains fuses must also be checked for prope...

Страница 5: ...en ignored causes most phono stages to continue rolling off the highest octave signals coming from the phono pickup rather than turning the final corner and shelving to flat response at about 50 kHz C...

Страница 6: ...is instance a technically wrong setting is completely harmless for all equipment involved In the case of the MM input the typically higher cartridge output levels allow fixed resistor termina tion wit...

Страница 7: ...rs from the car tridge manufacturer s specs 5 SWITCH SELECTABLE AMPLIFIER GAIN Cartridge output levels and downstream line level interconnect drive voltage requirements can vary greatly between manufa...

Страница 8: ...o the STEELHEAD s VARIable output jacks 9 SEPARATE BUFFERED FIXED AND VARIABLE OUTPUTS Choice of constant level source for interconnection to a line level only pre amp or recorder and variable outputs...

Страница 9: ...then attach the grounded IEC power cable jack to the IEC plug Keep the power off until all other system connections are completed Proceed by connecting the input and output cabling to the signal sour...

Страница 10: ...ar make sure the mains power is off and mains cords are unplugged Then unplug the power supply from the preamp If the preamp has been powered up within the last 15 minutes stop and let the large inter...

Страница 11: ...mas tree lights in the attic no Be careful to straighten any bent tube pins prior to installation pin misalignment will make fitting the replacement tube difficult or impossible and may damage the soc...

Страница 12: ...GREEN while the transmitter is active As the battery voltage wanes the green light may flash RED briefly when the transmitter is switched on that s when the load on the battery is heaviest When the b...

Страница 13: ...assive volume control offers highest headroom option over silicon based devices Precautions when using the Remora Remote system Use only fresh alkaline 9 volt 006P batteries in the remote transmitter...

Страница 14: ...of another Remora enabled Manley preamplifier that may be nearby in range of the transmitter If necessary you may alter the specific short user number of the transmitter When you do so the receiver ca...

Страница 15: ...e Steelhead s receiver decoder is configured to be in programming mode looking for any new user number changes If the decoder detects the new user number programming string from an armed remote during...

Страница 16: ...Replace with correct fuse Bad or unplugged Check cables and outlets power cable AC outlet not energized Rolling Grayout Abandon California elect Libertarians Power supply pilot ON HEAD not responding...

Страница 17: ...uts install shorting plugs Replace jumper if necessary Establish inter chassis connec tion Check lead head shell continuity Check for proper connection Keep source lines away from transformers motors...

Страница 18: ...quipment WEEE Information for customers The European Parliament and the Council of the European Union have issued the Waste Electrical and Electronic Equipment Directive The purpose of the Direc tive...

Страница 19: ...Typically less than 2 degrees Inter channel differential gain Less than 0 5 dB from 20 Hz to 20 kHz any gain setting Dynamic Range 101 dB 1 kHz 1 THD 200 Ohm source 47 k Ohm input 55dB Gain 97 dB 1 k...

Отзывы: