Manley STEELHEAD RC Скачать руководство пользователя страница 14

The Remora system is highly resistant to false operation due to noise or other remote signals, but the range 

will be reduced if the competing signals or noise is very strong. If you experience intermittently poor range, 

brie

fl

 y try operating the equipment at another location free of possible sources of interference before contact-

ing your dealer or Manley Labs. 

Keep the remote and all other parts of the system away from rain or moisture of any sort. The Remora Re-

mote’s circuitry is extremely intolerant of moisture intrusion. In the event the remote transmitter gets wet, 

remove the battery immediately, disassemble the case and try to remove as much moisture as possible as soon 

as you can. Then let the assembly air-dry in a warm place for a day before re-assembling and testing. DO NOT 

disturb any trimpot settings or move the antenna components.

Remove the battery promptly when it becomes weak or discharged or if the remote transmitter is not going to 

be used for a protracted period of time. This will help prevent corrosion due to battery leakage.

The motorized volume attenuator may safely be actuated by hand, or by the motor under remote command. 

The attenuator has a slip-clutch transmission, so it is safe to occasionally over-ride the motorized action by 

hand, or let the clutch slip after the attenuator reaches its end stop. However, the motorized attenuator assem-

bly will last longer if these actions are avoided.

How to establish the digital link (pairing) between the Remora transmitter and the receiver:

Each transmitter and receiver-decoder set is designed to respond to a speci

fi

 c data string as programmed into 

the transmitter and later acknowledged by the receiver-decoder. A small set of user-de

fi

 ned user-numbers is 

used as part of the data string so that the remote system can be programmed to avoid unwanted operation of 

another Remora-enabled Manley preampli

fi

 er that may be nearby, in range of the transmitter. 

If necessary, you may alter the speci

fi

 c short user-number of the transmitter. When you do so, the receiver can 

easily be reprogrammed to follow the changes and react to the new user-number. Having unique handshake 

ID codes is important for RF remotes since unlike infrared systems, the remote’s RF commands can penetrate 

walls, 

fl

 oors, and doors, which might operate other Manley Remora-enabled gear if they all had the same user-

numbers!

The user-numbers are a pair of single-digit numbers created by hitting the up and down buttons during a 

remote transmitter programming session. How to program the user-numbers is one of those procedures that is 

harder to write down than to actually do physically. 

To get acquainted with the remote transmitter itself, we’ll start with a simple matter of determining the Remo-

ra Remote’s user-number setting without changing the user-number. This requires only one action by you, the 

user. You’ll get to see some of the Remora Remote’s “modes” as indicated by the LED lamp.

How to query the Remora transmitter to see what user-number is already programmed:

Press and hold both the up and down buttons for about 0.5 seconds. Release the buttons when you see the LED 

change from dim green to 

fl

 ashing dim yellow. 

The LED will 

fl

 ash dim yellow for about three seconds. Be careful not to touch any buttons while the LED is 

fl

 ashing dim yellow as the remote is in the program mode during this time.

The 

fl

 ashing dim yellow LED will time out and will then go dark for a moment. Then the LED will recite the 

user-number by 

fl

 ashing a string of GREEN (up) blinks, then a string of RED (down) blinks. The user-number 

may range from the smallest value of 1 green, 1 red (1,1) up to a maximum of 7 green and 7 red (7,7). As you 

can see, up to 49 different user-numbers are available.

Once the user-number readout event lapses, the remote falls back to normal operation.

How many GREEN blinks?     (----- , -----)    How many RED blinks?

 

           UP 

   This is your user-number. 

     DOWN

14

Содержание STEELHEAD RC

Страница 1: ...MANLEY STEELHEAD RC MM MC GRAMOPHONE CARTRIDGE PREAMPLIFIER OWNER S MANUAL MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 USA TEL 1 909 627 4256 FAX 1 909 628 2482 www manley com...

Страница 2: ...NTENTS SECTION PAGE INTRODUCTION 3 INSTALLATION PRECAUTIONS 4 FEATURES AND APPLICATIONS 5 OPERATIONAL NOTES 9 REMORA REMOTE CONTROL OPERATING INSTRUCTIONS 12 TROUBLESHOOTING 16 MAINS CONNECTIONS 18 SP...

Страница 3: ...bility UNPACKING Unpack the preamplifier carefully and make sure that all supplied accessories are present Examine all items for any possibility of shipping damage All six tubes should be standing at...

Страница 4: ...ipment If however the preamp provenance is unknown then the mains voltage selector switch should be checked and reset to the correct voltage if necessary The mains fuses must also be checked for prope...

Страница 5: ...en ignored causes most phono stages to continue rolling off the highest octave signals coming from the phono pickup rather than turning the final corner and shelving to flat response at about 50 kHz C...

Страница 6: ...is instance a technically wrong setting is completely harmless for all equipment involved In the case of the MM input the typically higher cartridge output levels allow fixed resistor termina tion wit...

Страница 7: ...rs from the car tridge manufacturer s specs 5 SWITCH SELECTABLE AMPLIFIER GAIN Cartridge output levels and downstream line level interconnect drive voltage requirements can vary greatly between manufa...

Страница 8: ...o the STEELHEAD s VARIable output jacks 9 SEPARATE BUFFERED FIXED AND VARIABLE OUTPUTS Choice of constant level source for interconnection to a line level only pre amp or recorder and variable outputs...

Страница 9: ...then attach the grounded IEC power cable jack to the IEC plug Keep the power off until all other system connections are completed Proceed by connecting the input and output cabling to the signal sour...

Страница 10: ...ar make sure the mains power is off and mains cords are unplugged Then unplug the power supply from the preamp If the preamp has been powered up within the last 15 minutes stop and let the large inter...

Страница 11: ...mas tree lights in the attic no Be careful to straighten any bent tube pins prior to installation pin misalignment will make fitting the replacement tube difficult or impossible and may damage the soc...

Страница 12: ...GREEN while the transmitter is active As the battery voltage wanes the green light may flash RED briefly when the transmitter is switched on that s when the load on the battery is heaviest When the b...

Страница 13: ...assive volume control offers highest headroom option over silicon based devices Precautions when using the Remora Remote system Use only fresh alkaline 9 volt 006P batteries in the remote transmitter...

Страница 14: ...of another Remora enabled Manley preamplifier that may be nearby in range of the transmitter If necessary you may alter the specific short user number of the transmitter When you do so the receiver ca...

Страница 15: ...e Steelhead s receiver decoder is configured to be in programming mode looking for any new user number changes If the decoder detects the new user number programming string from an armed remote during...

Страница 16: ...Replace with correct fuse Bad or unplugged Check cables and outlets power cable AC outlet not energized Rolling Grayout Abandon California elect Libertarians Power supply pilot ON HEAD not responding...

Страница 17: ...uts install shorting plugs Replace jumper if necessary Establish inter chassis connec tion Check lead head shell continuity Check for proper connection Keep source lines away from transformers motors...

Страница 18: ...quipment WEEE Information for customers The European Parliament and the Council of the European Union have issued the Waste Electrical and Electronic Equipment Directive The purpose of the Direc tive...

Страница 19: ...Typically less than 2 degrees Inter channel differential gain Less than 0 5 dB from 20 Hz to 20 kHz any gain setting Dynamic Range 101 dB 1 kHz 1 THD 200 Ohm source 47 k Ohm input 55dB Gain 97 dB 1 k...