1. Important Safety Instructions

1.

Water and Moisture

 – Do not use The 

 near any source of water or in excessively moist 

environments. 

2.

Object and Liquid Entry

 – Care should be taken so that objects do not fall, and liquids are not 

spilled, into the enclosure through the openings. 

3.

Heat & Ventilation

 – When installing The 

 in a rack or any other location, be sure there 

is adequate ventilation. Improper ventilation will cause overheating, and can damage the unit. 
The unit should be situated away from heat sources, or other equipment that produce heat.  

4.

Power Sources

 – The 

 has an internal universal power supply which can operate in any 

country. It has an input voltage range of 90-260 VAC at 50/60 Hz.

5.

Cleaning

 - The 

 can be cleaned with just a damp cloth, or alcohol/methylated spirits for 

more stubborn marks.

6.

Damage

 - If after unpacking your 

 there are signs of shipping damage, contact your 

dealer. 

7.

Servicing

 - Do not attempt any servicing without consulting your dealer or Manley 

Laboratories, Inc. The user should not attempt to service the unit beyond that described in the 
operating instructions. All other servicing should be referred to qualified service personnel. 
This unit has 

high voltages

 present, even after the power has been switched off.

8.   

DO NOT

 connect the AC supply cord until all other connections have been made. Afer initial 

power up the power LED will “blink” for thirty seconds. The unit remains in MUTE until this 
warm up period has elapsed. 

ELOP+

ELOP+

ELOP+

ELOP+

ELOP+

2. Getting Started

Unpacking your MANLEY 

The ELOP+ is secured in its packing carton by two Duracell foam end-caps.

Hold the unit by the middle and simply lift the unit vertically straight out of the box.

After it has been unpacked, check that nothing is loose inside when handling the unit. The unit is 
shipped with the vacuum tubes installed. Make sure they are not loose by looking through the vent 
holes on the top cover. Ensure they are standing upright in their sockets.

It is advisable to keep the original packaging. In the event of servicing or relocating, the original 
packaging ensures that the unit will always be shipped safely.

This package contains the following;

1 x Manley ELOP+ Stereo Limiter Compressor
1 x Manley ELOP+ Owner’s Manual
1 x IEC Power Cable
1 x Warranty Registration Card
1 x Warranty Statement

ELOP+:

Содержание ELOP+

Страница 1: ...OWNER S MANUAL ELECTRO OPTICAL VACUUM TUBE LIMITER COMPRESSOR R...

Страница 2: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee t...

Страница 3: ...ranty by Manley Laboratories Inc for any purpose or give rise to any liability of Manley Laboratories Inc 2015 COPYRIGHT Manley Laboratories Inc All rights reserved This manual and any associated artw...

Страница 4: ...t described in the operating instructions All other servicing should be referred to qualified service personnel This unit has high voltages present even after the power has been switched off 8 DO NOT...

Страница 5: ...nd well with perceived loudness HP SC CONTROL The High Pass Side Chain filter is factory set to 80Hz When this switch is engaged and illuminated everything above 80Hz will drive the limiting or compre...

Страница 6: ...channel is compressed individually It becomes noticeable when a loud element that is panned to either edge of the stereo field raises the level of the program to the compressor s threshold causing its...

Страница 7: ...NPUT TRANSFORMER BALANCED CH1 LEFT PIN 1 GROUND PIN 2 PIN 3 XLR OUTPUT IMPEDANCE BALANCED CH2 RIGHT PIN 1 GROUND PIN 2 PIN 3 XLR INPUT TRANSFORMER BALANCED CH2 RIGHT PIN 1 GROUND PIN 2 PIN 3 IEC MAINS...

Страница 8: ...gh headroom However there are many poor examples of tube circuits in the field and many ways to butcher the quality We chose to use our favorite simple tube line amplifier circuit which we also use in...

Страница 9: ...meter where the ratio becomes low again but this would be a severe setting that few engineers could use Distortion becomes audible at very deep limiting In a tech shop it is easy to drive the limiter...

Страница 10: ...ere sometimes Obviously we pull out this trick when two tracks are stepping on each other and EQ isn t making enough room for clarity Trick 4 Drive the compressor from an AUX send and return it to a c...

Страница 11: ...t it is not touching any metal You may have cured a non loop hum Some gear radiates a magnetic field and some gear especially if it has transformers might receive that hum The unit would have to physi...

Страница 12: ...are straight and align with the receptacles of the tube base before pressing down firmly to locate the tube correctly GROUND LIFT JUMPER If necessary the Circuit Ground can be disconnected from the Ch...

Страница 13: ...the actual gain reduction accurately You will probably need to increase the oscillator 10 dB to get Limiting Adjust REDUCTION controls to reduce the signal to 4dB Switch METERS to REDUCTION Adjust 2...

Страница 14: ...path Bypasses limiter this is not a hardwire bypass Unity Gain Set Input Attenuator 1 00 o clock Maximum Gain 13 dB Common Mode Rejection Ratio CMRR 77dB BW 22Hz 22Khz 4dBu 1Khz sine Limiter Ratio 10...

Страница 15: ...13 11 Recall Sheet ARTIST SONG INSTRUMENT TRACK MIC NOTES DATE ENGINEER ARTIST SONG INSTRUMENT TRACK MIC NOTES DATE ENGINEER IN IN IN IN...

Страница 16: ...Rev 1 5 ZF 2017 Designed Handcrafted in the USA Manley Laboratories Inc 13880 Magnolia Avenue Chino CA 91710 USA T 1 909 627 4256 www manley com Z Z...

Отзывы: