Part Number 000007646 Rev 02 5/20 9
Pre-Installation Checklist
Location: Floor drain available
– A floor drain for the
dispenser should be available. We recommend that you
vent the drain at the back of the dispenser to reduce
buildup of algae and improve drainage. Drain tubing
should be 1/2" I.D. at minimum.
Location: Avoid heat sources
– Avoid placing the ice
machine near heat sources such as radiators, heating
vents and direct sunlight. Avoid placing air-cooled ice
machines in kitchens, due to grease, flour, or other
particles, which can collect on the condenser and
fan blade, increasing ice machine maintenance and
reducing ice machine efficiency.
Location: On a solid floor
– The dispenser and ice
maker should be sitting on a good, solid, level floor or
surface.
Location: Do not obstruct traffic
– The dispenser
should not extend from the wall in a way that obstructs
traffic through the area.
Electrical
– Proper electrical voltage is available.
Receptacle is available and within six feet.
n
Warning
Never use an extension cord. If an electrical outlet is not
within six feet, have proper amperage outlet installed.
The dispenser must be grounded in accordance with all
local and national electrical codes.
Clearances for top and both sides of ice machine
– Use clearances specified in the ice machine’s
Installation, Use and Care Manual.
Clearance behind ice machine for dispenser and
drains
– The location must allow enough clearance
for the water and drain connection at the rear of the
dispenser.
Back of ice machine to be flush with back of
dispenser
– This allows installation of the supplied
mounting clip (metal plate) which secures the ice
machine to the dispenser.
Separate drains
– a separate drain line is required for
the ice machine, in addition to a drain line for the S
Series Dispenser. Vent all drain lines.
Water filtration
– Water filtration is strongly
recommended in order to increase the performance of
the ice machine and reduce maintenance costs.
For full information about ice machine installation, including
plumbing lines, connections and electrical requirements, see
the ice machine installation manual.
,
Caution
The dispenser must be protected if it will be subjected
to temperatures below 32°F (0°C). Failure caused by
exposure to freezing temperatures is not covered by the
warranty.
Section 2
Installation
Содержание S160 Series
Страница 2: ......
Страница 8: ...8 Part Number 000007646 Rev 02 5 20 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...12 Part Number 000007646 Rev 02 5 20 Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 16: ...16 Part Number 000007646 Rev 02 5 20 Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 22: ...22 Part Number 000007646 Rev 02 5 20 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 25: ...Part Number 000007646 Rev 02 5 20 25 Section 5 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 26: ...26 Part Number 000007646 Rev 02 5 20 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 27: ......