Maintenance
Section 4
4-2
Part No. 80-1640-3
Cleaning the Condenser
GENERAL
A dirty condenser restricts airflow, resulting in
excessively high operating temperatures. This reduces
ice production and shortens component life. Clean the
condenser at least every six months. Follow the steps
below.
1. Clean the outside of the condenser with a soft brush
or a vacuum with a brush attachment. Be careful not
to bend the condenser fins.
2. Shine a flashlight through the condenser to check
for dirt between the fins. If dirt remains:
A. Blow compressed air through the condenser fins
from the inside. Be careful not to bend the fan
blades.
B. Use a commercial condenser coil cleaner.
Follow the directions and cautions supplied with
the cleaner.
3. Straighten any bent condenser fins with a fin comb.
Straighten Bent Condenser Fins
4. Carefully wipe off the fan blades and motor with a
soft cloth. Do not bend the fan blades. If the fan
blades are excessively dirty, wash with warm, soapy
water and rinse thoroughly.
!
Warning
Disconnect electric power to the ice machine head
section and the remote condensing unit at the
electric service switches before cleaning the
condenser.
!
Warning
The condenser fins are sharp. Use care when
cleaning them.
!
Caution
If you are cleaning the condenser fan blades with
water, cover the fan motor to prevent water
damage.
SV1515
FIN
COMBS
CONDENSER
“COMB” DOWN
ONLY
Содержание QD0282A
Страница 3: ......
Страница 8: ...Part No 80 1375 3 4 Table of Contents Revised 6 2003 ...
Страница 13: ...Section 1 General Information Part No 80 1375 3 1 5 THIS PAGE INTENTIONALLY LEFT BLANK Revised 6 2003 ...
Страница 14: ...General Information Section 1 1 6 Part No 80 1375 3 Revised 6 2003 ...
Страница 42: ...Ice Machine Operation Section 3 3 8 Part No 80 1375 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 6 2003 ...