Part Number 040005626 5/17
63
Safety Limit Checklist
The following checklists are designed to assist the
service technician in analysis. However, because
there are many possible external problems, do not
limit your diagnosis to only the items listed.
Safety Limit #1
Freeze time exceeds 60 minutes for 3 consecutive
freeze cycles.
Possible Cause Checklist
Improper installation
•
Refer to “Installation/Visual Inspection Checklist”
on page 55
Water System
•
Float switch or water escaping water trough
•
Low water pressure (20 psig min.)
•
High water pressure (80 psig max.)
•
High water temperature (90°F/32.2°C max.)
•
Clogged water distribution tube
•
Dirty/defective water inlet valve
•
Defective water pump
Electrical System
•
Harvest cycle not initiated electrically
•
Contactor not energizing
•
Compressor electrically non-operational
•
Restricted condenser air flow
•
High inlet air temperature (110°F/43.3°C max.)
•
Condenser discharge air re-circulation
•
Dirty condenser fins
•
Defective fan cycling control
•
Defective fan motor
•
Dirty condenser
Содержание MD0420A
Страница 2: ......
Страница 28: ...28 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Страница 40: ...40 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Страница 48: ...48 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Страница 86: ...86 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Страница 115: ...Part Number 040005626 5 17 115 Using Pinch Off Tool SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING ...
Страница 126: ...126 Part Number 040005626 5 17 This Page Intentionally Left Blank ...
Страница 128: ...128 Part Number 040005626 5 17 M0420 M0500 M0700 M1000 1 PH SELF CONTAINED AIR WATER COOLED ...
Страница 131: ......