background image

14

 

specifications 

 

Available in 120 V (NEMA) and 220 V (IEC) models 

 

•  Outlets: 8 NEMA (120 V), 6  surge only / 2 surge only; 7 IEC (220 V), 6 back-up + surge /  

  1 Schuko surge only 

•  Times:  

  -  Backup: 5 minutes at full load; 12 minutes at 50% load; 40 minutes at varying loads (typical with 

    PC and 15” LCD monitor at 85 W) 

  -  Recharge: 8 hours typical (10 hours maximum) 

  -  Transfer: 4-8 ms typical (10 ms maximum) 

•  Communications ports: RJ-45 (USB/RS232 interface), Emergency Power-Off (EPO) 

•  Telephone/fax/network ports: RJ-11/RJ-45 ports (1 in / 1 out), surge protected 

•  Nominal voltage: input, 115 V (230 V), output 115 V (230 V) 

•  Voltage range: input, 115 V +20% / –25% (230 V +20% / –25%) 

•  Frequency range: 50/60 Hz (auto sensing) 

•  Voltage regulation: 115 V +/– 13% 

•  Noise filter: full-time EMI / RFI filtering; 100 kHz to 10 MHz 

•  Frequency regulation: 50/60 Hz +/– 1% 

•  Waveform: pure sine wave 

•  Battery: capacity, 12 V / 7 Ah x 4; type, sealed and maintenance-free (lead acid) 

•  Temperatures (°C): operation, 0 to 40; storage, -20 to 40 

•  Operation relative humidity: 0 to 95% (non-condensing) 

•  LED indicators: Online, Overload, On Battery and Bad Battery 

•  Audible alarms: Overload, On Battery, Low Battery

Note:

 Specifications may change without notice.

Содержание 168205

Страница 1: ...MAN 168205 UM 0606 08 line interactive rackmount uninterruptible power supply USER MANUAL MODEL 168205...

Страница 2: ...c voltage regulation AVR cold start capability and diagnostics 1120 Joules telephone fax and network surge protection Circuit breaker protection offers quick recovery from overload and short circuit e...

Страница 3: ...commended Always disconnect the input power cord from the wall outlet before replacing the battery Do not dispose of the battery in a fire as the battery may explode Do not open or mutilate the batter...

Страница 4: ...S is furnished with a six foot line cord terminated with a standard NEMA 5 15P three pronged plug The UPS must be plugged into a two pole three wire grounding receptacle If an extension cord must be u...

Страница 5: ...ensure that your computer equipment will be protected during a utility failure and that you receive expected run time it is important that the total power needs of the equipment not exceed the capacit...

Страница 6: ...en release it to run a 10 second self test routine The UPS will transfer your equipment to power derived from its internal battery and run a self test controls iNdicators 1 On Off Test Button The On O...

Страница 7: ...becomes weak or disconnected this red LED will light indicating the battery must be replaced The alarm will beep three times at one minute intervals if the battery is bad or disconnected and will beep...

Страница 8: ...e UPS detects an overload at this point turn off the UPS and decide which equipment will be left unprotected Reset the breaker after the overload or short circuit is released then restart the UPS NOTE...

Страница 9: ...ut jack NOTE This connection is not needed to properly use the UPS 15 Emergency Power Off EPO Port This lets you turn off the UPS remotely using the provided cable Connect the EPO port of your UPS to...

Страница 10: ...LED Fault LED UPS Status Green 3 Yellow 4 Yellow 5 Red 6 Alarm Indication On X X X X AC mode Blinking X X X X AVR mode X On X X 1 beep 10 second intervals DC mode X X X On X Internal fault X On X X 1...

Страница 11: ...24 hours without a load 1 Remove the faceplate by first pulling open the latch on the front left of the UPS where the MANHATTAN logo is as shown at top right then loosening the two recessed screws th...

Страница 12: ...12 mounting procedures...

Страница 13: ...even and the UPS is briefly transferring UPS protects against abnormal utility voltages though normal line connected equipment to its backup power is present power source The input circuit breaker tr...

Страница 14: ...twork ports RJ 11 RJ 45 ports 1 in 1 out surge protected Nominal voltage input 115 V 230 V output 115 V 230 V Voltage range input 115 V 20 25 230 V 20 25 Frequency range 50 60 Hz auto sensing Voltage...

Страница 15: ...damage to electronic equipment that is not UC UL CSA or CE listed d damage to UC UL CSA or CE listed equipment not caused by power or phone line transients such as spikes or surges e damage caused by...

Страница 16: ...rademarks or registered trademarks of their respective owners www manhattan products com MANHATTAN offers a complete line of PC Components Peripherals Cables and Accessories Ask your local computer de...

Отзывы: