![M&S Armaturen PAMS DA Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/mands-armaturen/pams-da-series/pams-da-series_operation-manual_682541010.webp)
10
R
e
v
.2
/
01
.0
7
.2
0
1
6
Pneumatic actuator PAMS NC/NO/DA
9
Technical Data
9.1
Torques, permissible operating pressures and air consumption
Table 4: Torques, permissible operating pressures and air consumption
Variant
Maximum closing
moment [Nm]
Operating
pressure
[MPa]
Operating
pressure
[bar]
Air consump-
tion
[l/stroke]
NC/NO
size 0
35
0.48-0.80
4.8-8.0
0.8-1.2
NC/NO
size 1
65
0.48-0.80
4.8-8.0
1.2-2.0
NC/NO
size 2
100
0.48-0.80
4.8-8.0
3.0-5.0
DA size 0
50 (6bar)
0.30-0.80
3.0-8.0
0.5-1.2
DA size 1
80 (6bar)
0.30-0.80
3.0-8.0
0.8-2.0
DA size 2
130 (6bar)
0.30-0.80
3.0-8.0
1.9-5.0
9.2
Requirements control air
Table 5: Requirements control air
Requirement
Quality class
Standard
Solids content
6
acc. to ISO 8573-1
Water content
4
acc. to ISO 8573-1
Oil content
3
acc. to ISO 8573-1
9.3
Operating temperatures
Permitted operating temperatures from +1C° to max. +60C°.
The operating temperature depends on the fitting to be actuated.
10 Cleaning
Clean the pneumatic actuator with commercial cleaning agents.