you will be able to select the operating time in increasing 5 minutes
(up to 180 minutes maximum), decreasing by 1 minute.
The time will be counted down in minute steps, where upon the
display returns to the prior status (HEAT, TEMP). If you want to see
the remaining time, you can press “TIMER”.
Once the time is up, an acoustic signal sounds and the unit
automatically goes into standby mode. If you want to cancel the
TIMER function, simply press the ON/STANDBY key to switch off and
repeat to restart.
Utensils suitable for this appliance
Compatible Pans:
Steel or cast iron, enamelled iron, stainless steel, flat-bottom pans/
pots with a base diameter of 12 to 24 cm. (or with logo of induction
cooker compatible
)
Non-compatible Pans:
Heat-resistant glass, ceramic container, copper, aluminium pans/
pots. Rounded-bottom pans/pots with a base of less than 12 cm.
Maintenance
Clean after each use. Disconnect plug and wait until the unit has
cooled down. If the pots/pans are used without being cleaned,
as this may result in discoloration or stains. Do not use fuel,
paint thinner, scrubbing brush or polishing powder to clean the
induction stove.
Wipe down the unit using a dish washing agent and a damp cloth.
Use vacuum cleaner to suck up dirt from the air intake and exhaust
vent.
Never run water over the unit (if water gets inside it may cause
malfunction).
Error Code List:
• If LED-display shows the error code, please reference to the
solution as following.
Error Code
Cause and Solution
The unit is in
standby mode,
but the LED-
display shows
“---”, and the
unit sounds
“Dee, Dee, …”
1. You are using the cookware without the
magnetism bottom or the diameter of the
bottom is less than 12cm. Please use the
cookware with magnetic and flat base, such as
the iron or cast iron cookware, the cookware
with a 18/0 stainless steel base. And all
cookware with a base whose diameter is 12 to
24cm.
The device will enter into standby mode after
10 second without the suitable cookware.
Press ON/STANDBY to restart the unit.
2.
After press ON/STANDBY press HEAT or TEMP
key to turn on the unit.
E01
Voltage is under 145V
E02
Voltage is over 275V
E03
The accessory and spare parts are damaged,
please contact the nearest authorized service
facility for trouble shooting, repair and
adjustment.
E06
The accessory and spare parts are damaged,
please contact the nearest authorized service
facility for trouble shooting, repair and
adjustment.
GB-6