14
1. Turn the „ - STOP - “ switch to the „STOP“ position.
2. When the radiator is shut off for a long time, it is advisable to close the gas valve.
Programmable thermostat for control of heating or A/C. During operation, real room temperature is
displayed as well as time and day in the week, selected program, its graphic depiction, ON/OFF,
temperature selection outside the program and the selected temperature (economy-comfort). It offers
choice from 8 pre-set programs (0 - 6 and 8) and 8 user adjustable programs (10 - 16 and 18). Two
temperature levels can be set (economy and comfort) in the range 5 – 35°C. The program No. 8 is
Anti-frost, heating is turned on when the temperature drops below 5°C and the measured temperature
and DF (defrost) symbol is blinking alternatively on the display.
:
1 Day in a week 3 Graphic depiction
5 Symbol of temperature
7 ON symbol
2 Time
4 Manually set temperature
6 Temperature
8 Program number
1. Switch the main electrical switch „0“ to the „I“ position.
2. Turn the control switch of individual heaters „ - STOP - “ manually „ “ or automatically “„ “
the electric network green indicator light will light up „ “ on the control box (the number of switches
will vary depending on the type of control box - OI 1 to OI 6. OI 1 controls 1 Helios heater, OI 6
controls 6 Helios heaters).
3. After the venting time (about 50 seconds) the infrared heater starts up and the green indicator light
lights up on the control box „ “ and orange indicator light at the bottom of the burner box of the
heater.
4. In case the burner is not fired (the orange lamp of operation on the control box is not alight), the cycle
is repeated twice. If it does not ignite even the third time, the red indicator light on the burner box lights
up to indicate an error. For unblocking the error state, the power supply of the heater must be
disconnected and reconnected (turn the control switch „ - STOP - “ to the „STOP“ position and
back to „ “ or „ “. If the infrared heater fails to work after multiple ignition cycles, call your service
organization.
5. The performance of two-stage infrared heaters can be chosen manually using switch MAX - MIN
(Only with two-stage heaters Helios D).
Содержание OI Series
Страница 1: ......
Страница 2: ...2 Zapojen 9 Provoz 9 Nastaven programu 10 Technick specifikace 11...
Страница 6: ...6...
Страница 7: ...7 T2S3 N L1Pe COMNO N L Pe L1 L1 N NT1 T1 T2 T2S3 S3 CYKY 5Jx1 5...
Страница 8: ...8 CYKY 5Jx1 5...
Страница 12: ...12 Wiring 19 Operation 19 Program setting 20 Technical specification 21...
Страница 16: ...16...
Страница 17: ...17 CYKY 5Jx1 5...
Страница 18: ...18 L H C Thermostat TP08 CYKY 5Jx1 5...
Страница 22: ...22 Anschluss 29 Betrieb 29 Programmeinstellung 30 Technische Spezifikation 31...
Страница 27: ...27 T2S3 N L1Pe COMNO N L Pe L1 L1 N NT1 T1 T2 T2S3 S3 CYKY 5Jx1 5 Netzanschlussleitung 230V 50Hz 230V 50Hz...
Страница 28: ...28 Thermostat Netzanschlussleitung 230V 50Hz Thermostat TP08 L H C 230V 50Hz CYKY 5J x 1 5...