SPECIALIZED COMPONENTS
ANCHOR PLATE (DTC-AP)
INSULATED WALL RADIATION SHIELDS
This support is used on a masonry fireplace
or on top of a furnace to provide a positive
connection to the chimney. It is not to be
used in contact with any combustible mate-
rial, such as on a wood floor.
INSTALLATION INSTRUCTIONS
Once the appliance is installed, bolt the anchor plate to it. Install the
chimney according to the installation instructions for the finish support
(DTC-FSC).
FACTORY-BUILT FIREPLACES
For chimneys installed on factory-built fireplaces, follow the installation
instructions accompanying the fireplace.
INSULATED RADIATION SHIELD (DTC-FSI)
It must be used in combination with an attic radiation shield (DTC-ISI)
when passing through an attic. This component provides a 2"-safety
clearance to combustible materials surrounding the chimney.
ANGLED INSULATED RADIATION SHIELD
(DTC-WRSI30/DTC-WRSI45)
It has been designed for use when a chimney passes through a wall at
an angle. (See figure 27 for application).