www.mc-techgroup.com SP2000,
SP2300, SP2400 | 1.00.03
15
Sample tube
Type
Part No.
Temperature
max. °C
Material
tube/connection part
Length
1)
mm
Length
max.
mm
Tube ø
o/i „d1“
mm
Adapter for
SP2000/AO
20S9395 (600)
/ SS316Ti
Adapter for
SP2000/AO
20S9397 (900)
/ Hastelloy
®
C4
* Sample tube with support adapter. Max.Temperature concern the area of the support adapter on approx. 200 mm length
depend on material 600/900 °C [1112/1652 °F].
** For gas sampling downstream wet scrubbers for droplet separation
1)
standard
2)
Please pay attention to the characteristic feature of ceramic in case of high and changing temperatures!
Other materials or versions on request.
For more information about sample tubes see data sheet 2.14
To prevent condensation between sample point and heated gas sample probe or in case of condensation in the
area of the connection piece heated sample tubes made of stainless steel with flange connection DN 65 PN 6 are
used.
Type
Max. process
temperature
Length max.
Tube ø o.
Temperature sensor
SP-30H1.1, heating max. 320°C
Max. 550 °C [1022
°F]
2.0 m
*
ø 42.2 mm
Fe-CuNi
SP-30H1.1V, heating max. 320°C
Max. 550 °C [1022
°F]
2.0 m
*
ø 42.2 mm
Fe-CuNi
SP30-H2, heating max. 320 °C
Max. 550 °C[1022
°F]
2.0 m
*
Ø 42.2 mm
PT100
SP35-H1.1, heating max. 320°C
Max. 550 °C [1022
°F]
0.175 m
ø 42.2 mm
Fe-CuNi
SP35-H2, heating max. 320 °C
Max. 550 °C
[1022 °F]
0.175 m
ø 42.2 mm
PT100
*
= standard
For more information about heated sample tubes see data sheet 2.15
In case of heavier dust loading of the process gas, we recommend using a prefilter under all circumstances in order
to prolong service life. This can be supplied with or without dead volume displacer depending on the response
times required. These filters can be screwed directly into the probe flange or via extension tubes fitted with volume
displacers.
Содержание SP Series
Страница 22: ...22 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 6 Mounting of sample tube or prefilter ...
Страница 38: ...38 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 18 Wiring plan of control unit 234B ...
Страница 40: ...40 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 19 Filter elements and gaskets Washer 93S0034 ...
Страница 48: ...48 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 24 SP2000 H basic version ...
Страница 49: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 49 Figure 25 SP2000 H with options ...
Страница 50: ...50 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 26 SP2300 H ...
Страница 51: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 51 Figure 27 SP2300 H filter elements ...
Страница 52: ...52 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 28 High temperature tube aluminium oxide AO ...
Страница 53: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 53 Figure 29 Heated sample tubes SP30 H ...
Страница 54: ...54 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com ...
Страница 55: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 55 Figure 30 Test gas feeding and blow back possibilities ...
Страница 56: ...56 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 31 SP2000 H 3VA MS NC B ...
Страница 57: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 57 Figure 32 SP2000 H 3VA MS NC C ...
Страница 58: ...58 SP2000 SP2300 SP2400 1 00 03 www mc techgroup com Figure 33 SP2000 H 3VA MS NO B ...
Страница 59: ...www mc techgroup com SP2000 SP2300 SP2400 1 00 03 59 Figure 34 SP2000 H 3VA MS NO C ...