![M&C 701 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/mandc/701/701_instruction-manual_3058886011.webp)
www.mc-techgroup.com
Temperature controller 701 | 1.01.00
11
2.
Connect the mains voltage terminals identified with
L1
and
N
to the supply voltage being sufficiently
protected by fuse.
3.
Connect the switching contact for ON/OFF for the consumer to the terminals
5
/
6
/
7
with the functions
NO
(normally open)
/
NC
(normally closed) /
COM
(potential).
Figure 6 Relay output K1 (zero-current state)
4.
Optionally, a multipole coupling socket can be mounted externally that will be wired with the temperature
controller according to the pin connection plan (see Figure 6). This enables you to make a simple, easy
servicing connection between the heated sample lines
3/4/5-N/M/H
or
PSP-4M (-W)
by means of the
multipole coupling connector (standard equipment of the heated sample lines) with the temperature
controller.
Figure 7
Pin assignment of the heated lines
3/4/5-
N
/M
/H or PSP-4M (-W)
3
1 Power
L
2 Pow er
N
4
6 Sensor
5 Sensor