6
PMA 50 EX | 1.01.04
www.mc-techgroup.com
3
ELECTRICAL STANDARDS
The electrical standard of electrical equipment corresponds to the safety regulations concerning the EN61010
and to the safety requirements of the European standards:
EN 61010
EN 61508
EN 60079-0:2012+A11:2013
EN 60079-1:2014
EN 60079-7:2015
for operation of the equipment in hazardous areas group II category 2. Attention must be paid to the Certifi-
cate of Conformity IBExU 16 ATEX 1192 (see appendix).
4
SAFETY INSTRUCTIONS
Note the following basic safety procedures when using this equipment:
Read these operating instructions carefully before start-up and use of the equipment! The infor-
mation and warnings given in these operating instructions must be heeded.
Attention must be paid to the requirements of the certificate of conformity (see appendix): IBExU 16
ATEX 1192.
Work on electrical equipment is only to be carried out by trained specialists as per the regulations
currently in force.
Attention must be paid to the requirements of
VDE 0100
when setting high-power electrical units
with nominal voltages of up to 1000 V, together with the associated standards and stipulations.
For use in hazardous area observe the relevant national and international instructions and regula-
tions.
Check the details on the type plate to ensure that the equipment is connected up to the correct
mains voltage.
Protection against touching dangerously high electrical voltages. Before opening the equipment, it
must be switched and hold no voltages. This also applies to any external control circuits that are
connected.
The equipment is only to be set within the permitted range of temperatures and pressures.
Check that the location is weather-protected. It should not be subjected to either direct sun, rain or
moisture.
Installation, maintenance, monitoring and any repairs may only be done by authorised personnel
with respect to the relevant stipulations.
Содержание 1803436
Страница 41: ...www mc techgroup com PMA 50 EX 1 01 04 41 Figure 10 Circuit diagram front board PMA50 EX ...
Страница 42: ...42 PMA 50 EX 1 01 04 www mc techgroup com Figure 11 Assembly front board PMA50 EX ...
Страница 43: ...www mc techgroup com PMA 50 EX 1 01 04 43 Figure 12 Circuit diagram mains adapter PMA50 EX ...
Страница 44: ...44 PMA 50 EX 1 01 04 www mc techgroup com Figure 13 Assembly connection mains adapter PMA50 EX ...
Страница 48: ...48 PMA 50 EX 1 01 04 www mc techgroup com ...
Страница 49: ...www mc techgroup com PMA 50 EX 1 01 04 49 ...
Страница 50: ...50 PMA 50 EX 1 01 04 www mc techgroup com ...
Страница 51: ...www mc techgroup com PMA 50 EX 1 01 04 51 ...
Страница 52: ...52 PMA 50 EX 1 01 04 www mc techgroup com ...
Страница 53: ...www mc techgroup com PMA 50 EX 1 01 04 53 ...