47
solutions creator
ENGLISH
MALFUNCTIONING, CAUSES, TROUBLE-SHOOTING
DISPLAY
MALFUNCTIONING
CAUSES
TROUBLE-SHOOTING
Err 11
During launch Err 11 appears on the display
1. Passage through zero sensor defective in optoelectronics
2. The motor will not turn
1.
a) check optoelectronic card connection.
b) check the optoelectronic card is protected from daylight and cover if
necessary;
c) if the defect persists check and if necessary replace the optoelectronic
card.
2. Check electrical part.
Err 17
At end of launch Err 17 appears on display
1. Weight out of regulation field (weight necessary for balancing the wheel
is above 250 grams)
1.
a) Check that the wheel is correctly fixed on the flange;
b) find (in any case) the external position, apply a 100 gram weight and
launch a run.
Err 18
Err 18 appears on display
1. Wheel data not set.
1. Set the wheel data before starting the measuring cycle.
Err 20
During measuring cycle Err 20 appears on display: the wheel
speed has gone below the minimum for measurability.
1. 1 Brake pedal operated during the measurement
2. Motor rotation speed irregular.
1. Avoid pressing the brake pedal when the motor is operating.
2. beware of knocking the machine during the measuring cycle. check mains
voltage (probably low).
Err 21
During measuring cycle Err 21 appears on display: possible
electrical fault
1. The electronic card has found a condition of danger connected to a too-
high wheel speed during an inactive machine phase (the shaft rotates at
high speed without the operator having pressed the START command); the
electric power is deactivated.
1. Switch off the machine, lower the guard and switch the machine back on
without moving the wheel; if the error persists, check (and replace if neces-
sary) the electric or electronic part (control panel or encoder card).
Err 22
During the launch Err 22 appears on display
1. Some fault in the optoelectronic signals.
1.
a) check the optoelectronic card is protected from daylight and cover if
necessary;
b) if the defect persists check and if necessary replace the optoelectronic
card.
c) check and if necessary replace the control panel electronic card.
Err 23
When the START button is pressed the display reads Err23
1. The gauge for measuring distance is not in the neutral position.
1.
a) Check that the gauge is in the neutral position.
b) Check the A5 analogue figure (approx. 200).
c) Repeat the gauge calibration procedure.
EEE EEE
EEE EEE appears on the display
1. Two keys pressed together.
2. Keyboard defective.
1. Press one key at a time.
2. Check and if necessary substitute the control panel electronic card.