NOTICE
•
The installer MUST test for proper connection and functionality of the operator and its accessories
before leaving the job site.
•
The installer should also perform a demonstration for the end-user.
6.1
Low Voltage (Controls) and High Voltage (Power) Connections
1. Route the power line wires either from
the right or from the left of the control
box, as shown in Figure 14.
2. Route all low voltage control wires, as
shown in Figure 14. KEEP LOW
VOLTAGE WIRES SEPARATE FROM
LINE VOLTAGE WIRES.
3. USE COPPER CONDUCTORS ONLY.
6.2
Main Power Supply Connection
Single-Phase (115/230V)
Three-Phase (208/230-460-575V)
Correct motor rotation: Switch the BLUE and ORANGE
motor wires on the power board.
Correct motor rotation: Switch ANY TWO incoming lines
(phase) on the power terminal block.
For technical support, please call
1-800-361-2260
for more information
Line 3
Line 2
Line 1
P
o
w
e
r
Te
rm
in
a
l B
lo
ck
NEUTRAL
LIVE
P
o
w
er
T
er
m
in
al
B
lo
ck
Figure 14 - Low Voltage (Controls) and
High Voltage (Power) Connections
Control
Power