5
MODE SETTING
Wiring
Type
Wiring Type & Functions
Select
Switch
C2
(factory
preset)
Set select switch on 0
Momentary contact to open and stop, constant pressure to close with 3 buttons
station. Activation of safety devices will reverse the door during closing. Auxiliary
devices function as an Open control and to reverse door during closing.
B2
Set the select switch on 1
.
Momentary contact to Open/Close and Stop with 3 buttons station. Activation of
safety devices will reverse the door during closing. Auxiliary devices function as
Open/Close control and reverse the door during closing.
D1
Set the select switch on 2
.
Constant pressure to Open and constant pressure to Close. Activation of
safety devices will stop the door during closing.
E2
Set the select switch on 3
Momentary contact to open and constant pressure to Close. Release of Close
button activates the door upwards. Activation of safety devices will reverse door
motion to fully open position.
T
Set the select switch on 4
.
Momentary contact to Open / Close and Stop. Timer to Close if programmed,
safety devices reverse upon but will disable Timer to Close. Timer to close will
also be disabled if there is a power outage, a chain hoist is engaged or the stop
is pressed before elapsed time. The timer resumes its normal operation, once
the close cycle is completed.
TS
Set the select switch on 5
.
Momentary contact to Open / Close and Stop. Timer to Close if
programmed, safety devices reverse upon activation and will refresh Timer
to Close. Timer to close also gets refreshed, if there is a power outage, a
chain hoist is engaged or a stop button is pressed before elapsed time.
IMPORTANT NOTES:
•
STOP JUMPER
•
While testing the operator or adjusting the cams using the O/C/S buttons available on the
Electronic Control Board, a jumper should be placed between the #8 & #9. Once the tests or
adjustments completed the jumper should removed before connecting the wall 3-push buttons
station. Failure to remove the stop jumper,
the STOP BUTTON WILL NOT RESPOND
.
•
A stop jumper should be installed between #8 & #9 when using a Key switch, a single button
Radio control or a 2-buttons station (Open/Close).
IN THESE CONDITIONS NO STOP
COMMAND IS AVAILABLE TO STOP THE DOOR DURING THE TRAVELLING.
WARNING
MOTORIZED DOORS CAN CAUSE SEVERE INJURY OR DEATH. MANARAS STRONGLY
RECOMMENDS THE USE OF ENTRAPMENT PROTECTION SYSTEMS, ESPECIALLY IN THE CASES
OF MOMENTARY CONTACT TO CLOSE (B2 WIRING) AND TIMER TO CLOSE (T & TS).