Important changeover instructions
Please read the following instructions carefully before changing the controller over to another
.
The following instructions apply to all the gate operators built with MA-100 logic controller
model: M-85 & MHD-85 – single-phase 115/120V. We have tried every effort to minimize the
time required to change over these boards.
NOTICE
Step by step changeover instructions
1. Disconnect all power to gate operator.
2. Remove the four bolts holding the MA-100 controller.
3. Install the Manaras-Opera logic controller. The controller is supplied with a pre-wired
transformer and shall be installed in the control box, depending upon the space available.
4. Fix the transformer. Locate a free space in the control box and secure the transformer supplied
with the new controller.
5. Remove the two 14-pole plug connector from the socket. One 14-poles connector is numbered
1 to 14 and the second one is numbered as 15 to 28.
6. Once the MA-100 controller is removed, replace it with Manaras-Opera Controller. Since the
new controller does not have any socket connector like MA-100, but instead is provided with
regular terminal strip numbered accordingly.
7. Remove all the wires from the 14-poles connector numbered 1 to 14. Remove 10-k ohms
resistor and two jumper wires between 1 to 9 and 1 to 10 permanently. Once all the wires are
removed, connect back all the wires to the corresponding numbers provided on the terminal
strip on Manaras-Opera controller. Make sure all the wires are connected to the respective
numbers.
8. Remove all existing wires on the second 14-poles connector, which are numbered as 15 to 28.
Once the wires are removed, connect back the wires from terminal # 16, 20, 21, 24 & 25 to
respective numbers on the new terminal strip provided on Manaras-Opera controller. If any
warning Lights were connected on 22 and 23 they should be removed.
9. Do not disconnect any external devices like push button station, safety edge, exit loop, safety
loop, radio control etc. We tried every aspect not to disturb these, but if you wish to use some
of the added features to this new controller refer to the instruction manual provided.
10.
Refer to the electrical drawing and instruction manual for more details
WARNING
Neglecting to follow these instructions will result in complete damage to the controller. If you