When the purifier no longer produces enough ozone to be effective, the ozone plate
should be cleaned. A good rule of thumb is every month. Some environments
cause ozone output to be reduced in a shorter time but other environments may
take longer.
To clean a plate, first turn the unit
off
and
UnPlUG
from outlet. Then remove
the 4”x4” plates from back of unit. Pull plates firmly in the center to remove from
the slot. With plate firmly supported in the hand apply a solution of warm water
and ammonia (50/50 solution is suggested) or a strong grease cutting detergent.
Scrub with a stiff brush if necessary. Be careful not to drop the plate or scrub off
the silicon. Clean both the metal screen and the ceramic tile. Rinse plate in hot
water and
DRy ComPlEtEly
before installing. If available you may use a hair
dryer to dry the plate. Reinstall plate, making sure it is secured and flush with the
back of the unit. Plug unit into a grounded electrical outlet; turn unit on and start
enjoying clean fresh air.
To clean needlepoint ionizer, first turn
off
and
UnPlUG
from outlet. Remove the
fan grill cover. The needle point ionizer will be easy to find in front of the fan by
looking for two pieces of wire. Take a q-tip or cotton swab dipped in alcohol and
clean any dust that may have accumulated on the needlepoints. This process
may be done when plates are being cleaned. While you have the front grill cover
off the unit you may also clean the fan and grill itself. To clean the fan, simply wipe
the blades with a damp cloth or vacuum. The grill cover may also be cleaned
with warm soapy water. Be careful that the fan grill cover is completely dry before
installing.
ClEanInG anD maIntEnanCE