AirCombi Spray Gun
MAMBA
Page
8
OPERATING MANUAL
5. Set-up
The spray gun is designed specifically for AirCombi spraying, i.e. the Spray gun can be used in Airless mode
as well as in Mixed Air mode. The atomization is accomplished by the pressure (adjustable from 0 up to 200
Bar) through a pump. The air is used to improve the atomization quality and to increase or decrease the fan
size by adjusting the proper fan regulator placed on the spray gun
WARNING: INJECTION HAZARD POSSIBLE. DO NOT SPRAY WITHOUT TIP IN PLACE. AL-
WAYS ENGAGE TRIGGER LOCK BEFORE REMOVING, REPLACING OR CLEANING TIP. NEVER
TRY TO CLEAN THE TIP WITH YOUR FINGERS.
To prevent hazardous concentration of toxic and/or flammable vapors, spray only in a prop
-
erly ventilated spray booth. Do not operate the spray gun unless ventilation fans are op
-
erating. Check and follow all of the Local and National Codes/Standards regarding exhaust
velocity requirements. Check and follow all local safety and fire codes.
5.1. Grouding
Check your local code and pump manual for detailed grounding instructions. Use only electrically conduc
-
tive fluid hoses. Ground the spray gun through connection to a properly grounded fluid supply hose and
pump.
5.2. Assembling the spray nozzle
Warning:
the proper nozzle size is essential for a good atomization on which depends the final result. The
nozzle size is determinated by the coatings used and the type of application. Ask to the coatings’ manufac
-
turer for the proper tip size.
1. Place the trigger lock in horizontal position in order to prevent accidental injection
WARNING: Before each nozzle change, assure to release the pressure in the spray gun and disconnect air
supply.
2. Unscrew the nut
3. Remove the air cap
4. Remove the nozzle into the air cap
5. Place the nozzle into the air cap
6. Place the air cap complete with the nozzle into the spray gun
7. Screw the nut onto the spray gun
5.3 Spray Gun Filter
We suggest always to use a Gun Filter, unless the coatings used do not require it. The mesh size of the gun
filter is determinated by the nozzle size. See the table at page 10 for the suggested filter size.
Содержание AirCombi
Страница 16: ...Technical data subject to change ...