background image

Before  Fall

After  Fall            Anchorage            

Allowance

Static line

deflection

length

of Lanyard

Energy 

Absorber

Extension

Height of  worker

Safety  Clearance 

Refer

Deflection Chart

Fig. 10

6.56 ft.

3.28 ft.

1.90 ft.

3.28 ft.

Table

Span Length 

Users

1

2

3

4

3.87

4.30

3.87

3.87

4.33

4.82

4.36

4.36

5.28

5.91

5.31

5.31

5.74

6.43

5.81

5.81

6.69

7.51

6.76

6.76

7.15

8.04

7.25

7.25

8.07

9.09

8.20

8.20

8.56

9.65

8.69

8.69

9.48

10.70

9.65

9.65

9.94

11.22

10.14

10.14

10.89

12.30

11.12

11.12

11.35

12.83

11.58

11.58

12.30

13.95

12.56

12.56

12.76

14.44

13.02

13.02

13.68

15.49

14.01

14.01

14.14

16.01

14.50

14.50

15.06

17.06

15.49

15.49

15.52

17.59

15.98

15.98

Deflection Chart

15 ft.
20 ft.
25 ft.
30 ft.
35 ft.
40 ft.
45 ft.
50 ft.
55 ft.
60 ft.
65 ft.
70 ft.
75 ft.
80 ft.
85 ft.
90 ft.
95 ft.
100 ft.

Step 8 : Now lifeline may be taken off from the anchorage. 
Step 9 : After uninstallation, inspect the entire lifeline for any evidence of damage, wear, corrosion on 

tensioner body  and separation of rope fibers. 

Do not alter& misuse the equipment.
NOTE:-

Workplace conditions, including, but not limited to, flame, corrosive chemicals, electrical shock, sharp objects, machinery, abrasive

substances, weather conditions, and uneven surfaces, must be assessed by a Competent Person before fall protection equipment is selected.

The analysis of the workplace must anticipate where workers will be performing their duties, the routes they will take to reach their work, and the

potential and existing fall hazards they may be exposed to. Fall protection equipment must be chosen by a Competent Person. Selections must

account for all potential hazardous workplace conditions. All fall protection equipment should be purchased new and in an unused condition.

Fall protection systems must be selected and installed under the supervision of a Competent Person, and used in a compliant manner.

Fall protection systems must be designed in a manner compliant with all federal, state, and safety regulations.

Forces applied to anchors must be calculated by a Competent Person.

Harnesses and connectors selected must be compliant with manufacturer's instructions, and must be of compatible size and configuration.

A pre-planned rescue procedure in the case of a fall is required. The rescue plan must be project specific. The rescue plan must allow for

employees to rescue themselves, or provide an alternative means for their prompt rescue.

Store rescue equipment in an easily accessible and clearly marked area.

Training of Authorized Persons to correctly erect, disassemble, inspect, maintain, store, and use equipment must be provided by a Competent

Person.

Training must include the ability to recognize fall hazards, minimize the likelihood of

fall hazards, and the correct use of personal fall arrest systems.

NEVER use fall protection equipment of any kind to hang, lift, support, or hoist tools

or equipment, unless explicitly certified for such use.

Maintenance of equipment must be done according to manufacturer's instructions.

Equipment instructions must be retained for reference.

Prior to EACH use, all equipment in a fall protection system must be inspected for any

potential or existing deficiencies that may result in its failure or reduced functionality.

IMMEDIATELY remove equipment from service if any deficiencies are found.

Equipment must be inspected by a Competent Person at least every 

12

 months.

 

These inspections must be documented in equipment instruction manual and on

 

equipment inspection grid label.

Equipment must be inspected for defects, including, but not limited to, the absence

 

of required labels or

markings, improper form/fit/function, evidence of cracks, sharp edges, deformation,

 

corrosion, excessive heating, alteration, excessive wear, fraying, knotting, abrasion,

 

and absence of parts.

Equipment that fails inspection in any way must immediately be removed from use,

or repaired by an entity approved by the manufacturer.

No on-site repair of equipment unless explicitly permitted by the manufacturer.

Equipment subjected to forces of fall arrest must immediately be removed from use.

Snap hooks, carabiners, and other connectors must be selected and applied in a 

compatible fashion. All risk of disengagement must be eliminated. All snap 

hooks and carabiners must be self-locking and self-closing, and must never be 

connected to each other.

Age, fitness, and health conditions can seriously affect the worker should a fall 

occur. Consult a doctor if there is any reason to doubt a user's ability to withstand 

and safely absorb fall arrest forces or perform set-up of equipment.

Pregnant women and minors must not use this equipment. Physical harm may

still occur even if fall safety equipment functions correctly. Sustained post-fall

suspension may result in serious injury or death. Use trauma relief straps to

reduce the effects of suspension trauma. Allowable individual worker weight

limit (including all equipment), unless explicitly stated otherwise, is 130 lbs -

310 lbs.

IMPORTANT INFORMATION :

The Horizontal Anchor Line and the anchor points need to be above the user's

head, Horizontal anchor line is intended for use on span upto 100 ft, for a fall of  

up to 4 users, with anchor line fitted on spans of 15 ft to 100 ft, the typical peak 

line deflection from the original position are stated in table above.

MAINTENANCE, CLEANING, AND STORAGE

Repairs to 4-Person Rope HLL can only be made by a competent person or

an entity authorized by manufacturer. If a 4-Person Rope HLL fails inspection in

any way, immediately remove it from service, and contact manufacturer to

inquire about its return or repair.

Cleaning after use is important for maintaining the safety and longevity of 4-

Person Rope HLL.

WARNING- Failure to understand and comply with safety regulations may result in serious injury or 

death. Regulations included herein are not all-inclusive, are for reference only, and are not intended 
to replace a Competent Person's judgment or knowledge of federal or state standards.

Note:- 
HLL3001 is proved with steel O-Rings to be used as mobile anchor for the workers to get connected 

to the lifeline permanently. 