background image

Fluid Warming Cabinet

 

Operation, Maintenance and Installation Manual

 

Issue 18 

Page 3

 

Jun-23

 

Safety Instructions - Warnings 

Please read and understand this manual before using this device, if this device is used in a manner not specified 
by the manufacturer protection by the device may be impaired. 

Please refer to this manual for information wherever this warning symbol is displayed

 -

 

 

 

Be aware of 240 Voltage. 

 

Disconnect power when servicing. 

 

Mains power GPO must be in an accessible position so device can be 
isolated from mains power during service. 

 

If the supply cord is damaged it must be replaced by a special cord or 
assembly from the manufacturer or its service agent. 

 

Do not overload shelves. 

 

Do not obstruct hot air outlet above top shelf. 

 

Castors where fitted are for convenience but not as a means to be 
wheeled across thresholds or similar obstacles. Castors enable the device 
to be moved easily aside for cleaning the floor or making space.  

 

Wall mounted units must be mounted to load bearing walls. 

 

All cabinets should be located on a level floor surface and should never be 
operated on a sloping surface. 

 

Install temperature probes and element over temperature protection 
thermal cut-outs correctly.

 

This Warming Cabinet is not intended for use by persons (including 
children) with reduced physical, sensory, or mental capabilities, or lack of 
experience and knowledge. 

 

 

Содержание F105BT

Страница 1: ...state Issue 18 Jun 23 Head Office and Customer Service ABN 95 001 717 791 9 11 McKay Avenue PO Box 373 Leeton NSW 2705 Phone 61 2 6953 7677 Email info malmet com au Fluid Warming Cabinet Single Model...

Страница 2: ...rs 4 1 1 Device Operation 5 1 2 Control Display Features 5 1 3 Operating Features 5 1 4 Changing the set temperature lock out feature 6 1 5 Temperature Cut Out 6 1 6 Temperature Sensor Plate 6 2 0 Ins...

Страница 3: ...wever owing to Malmet Australia s policy of continuous improvement changes to these specifications may be made at any time without notice on the part of Malmet Australia Pty Ltd Certifications and Com...

Страница 4: ...be replaced by a special cord or assembly from the manufacturer or its service agent Do not overload shelves Do not obstruct hot air outlet above top shelf Castors where fitted are for convenience bu...

Страница 5: ...able 15 litres per shelf maximum load Single 420 Litre Fluid Warming Cabinets Models F420FS and F420C are designed to hold a maximum of 105 litres of fluid in 1 and 2 litre bottles and bags 420 litre...

Страница 6: ...age circuit breaker for approximately three hours This will allow any moisture in the heater to dry out The device can then be connected to an earth leakage circuit breaker protected circuit if requir...

Страница 7: ...c cut out fails a secondary safety bi metallic cut out temperature switch will switch off the power to the elements Fig 1 1 6 Temperature Sensor Plate When new product is introduced into the cabinet t...

Страница 8: ...Combination Conversion Kit This comprises a Floor Bench Skirt and a Rear Joining Bracket Conversion will take approximately fifteen minutes and requires a screwdriver only Carefully place the bottom w...

Страница 9: ...s wikimedia org w index php curid 55610678 Handling Weights of Device Net 47 195 kg Shipping 57 210 kg Shipping with crating 84 275 kg Handling of the device to installation site must be with fork lif...

Страница 10: ...ration Maintenance and Installation Manual Issue 18 Page 9 Jun 23 2 1 Service Connections Electrical Connection 240 Volt 10 Amp Plug into 10 Amp G P O 2 2 Device Dimension and Clearances F105BT Fluid...

Страница 11: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual Issue 18 Page 10 Jun 23 F210FS Fluid Warming Cabinet Freestanding with Floor Skirt...

Страница 12: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual Issue 18 Page 11 Jun 23 F260FS Fluid Warming Cabinet Freestanding with Floor Skirt...

Страница 13: ...not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge Children should be supervised to ensure they do not play wit...

Страница 14: ...her authorised personnel 1 Check electrical connections as per AS NZS 3551 2012 2 Perform temperature calibration Insert calibrated thermometer Allow cabinet temperature to stabilise Compare cabinet d...

Страница 15: ...r Service Display turns on Runs for approximately 1 hour then turns off Fan failure Switch off power supply at main and Call for Service Display is on but unit not heating Element failure Relay board...

Страница 16: ...Phase Hz 1 ph 50Hz Amps 2 8 Amps Watts 0 6 kW Environment operating conditions Temperature Relative Humidity 10 C to 25 C 30 to 70 Electrical Connection IEC right angle Power Cord with 3 Pin Plug 10 A...

Страница 17: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual Issue 18 Page 16 Jun 23 4 2 Wiring Diagram...

Страница 18: ...for issuing the relevant certificates of compliance these may differ from state to state CONDITIONS AND EXCLUSIONS Device must be installed and commissioned according to Malmet s instructions outline...

Страница 19: ...ther way from the purchaser to any other person To the extent permitted by law unauthorised use of any parts that were not supplied or approved for use in the applicable device by Malmet will result i...

Страница 20: ...component under this warranty Please complete details below Date Purchased Warranty Expiry Date Sold To For Service Contact PROOF OF PURCHASE Please retain your proof of purchase receipt invoice or c...

Страница 21: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual DCN 2970 P N 8 M00 84 900 Manufactured by Malmet Australia Pty Ltd ABN 95 001 717 791 www malmet com au...

Отзывы: