![Malmbergs 99 190 29 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/malmbergs/99-190-29/99-190-29_instruction-manual_698423030.webp)
30
Wall mount:
• 99 190 29
Top view
Side view
Helpful tips for installation
1. The optimal location for installation is at garden, corridor, staircase, entrance, garage, public
lavatory, outdoor parking area, home and office, etc.
2. Since the detector responds to temperature change, please avoid the following conditions:
• Avoid pointing the detector toward the objects whose surfaces are highly reflective, such as mir-
ror, glass, etc.
• Avoid mounting the detector near heat sources, such as heating vents, air conditioners, lights, etc.
• Avoid aiming the detector toward the objects which may be swayed in the wind, such as curtain,
tall plants, etc.
Fig. 2-B
5
5
0
16 m
16 m
7
7
180
O
Φ
10 m
Φ
14 m
Φ
32 m
H=2.5 m
Function
1. Auto mode
Under Auto mode, the load will turn on automatically when the movement is detected and the am-
bient light level is below the Lux setting value. When no movement is detected and the delay time
has expired, the load will turn off automatically.
2. Manual override for switching light on for 8 hours (Lux is independent)
When detector is standby under the auto mode, the can be bypassed to turn the light(s) on for 8
hours by series connecting a power supply switch.
OPEN
OPEN
Fig. 3
Fig. 4