34” Zircon Direct Vent
Through the Wall Vent Installation
The 34 Zircon Direct Vent can be installed with a through the wall kit available from Malm. The through
the wall vent kit consists of the following:
1 - Inner and Outer support box.
1 - Dura Vent 46DVA-GK flex to 4” x 6” to Direct Vent Pro.
1 - Dura Vent 46DVA-HSCH High Wind Sconce Termination.
The clearance to combustibles for the
DirectVent Pro coaxial vent is 2" on the
top of the pipe to a combustible and 1" on
the sides and bottom.
A minimum clearance of 12" must be
maintained from the top of the cover pipe
or elbow to the ceiling.
The horizontal run of venting must be
level, or have a 1/4-inch rise for every
1-foot of run towards the termination.
Never allow the vent to run downward. A
downward slope can trap heat and be
-
come a possible fire hazard.
The first step is to locate the center of
the horizontal pipe location. The mini
-
mum height is 68” from the floor to
the center of the support box. This is a
minimum height and may be exceeded.
The vent is required to be a minimum of
18” below any eves or roof overhang.
The location of the Horizontal Vent Termination on an exterior wall must meet all local and national
building codes, and must not be easily blocked or obstructed. Termination clearances are as follows:
(a) Clearance above the ground, veranda, porch, deck, or balcony: 12 inches minimum.
(b) Clearance to a window (operable or fixed closed) or door: 12 inches minimum.
(c) Vertical clearance to a ventilated soffit located above the Termination Cap (if soffit extends a horizon
-
tal distance of 2 feet out over the center line of the termination): 18 inches minimum.
(d) Clearance to an unventilated soffit: 12 inches minimum.
(e) Clearance to an outside corner: as tested by appliance manufacturer.
(f) Clearance to an inside corner: as tested by appliance manufacturer.
(g) Not to be installed above a meter/ regulator assembly within 3 feet horizontally from the center line
of the regulator.
(h) Clearance to a service regulator vent outlet: 6 feet minimum.
(i) Clearance to non-mechanical air supply inlet to a building or the combustion air inlet to any other
appliance: 12 inches minimum.
(j) Clearance to a mechanical air supply inlet: 6 feet minimum.
(k) Clearance above a paved sidewalk or paved driveway located on public property: refer to local code.
(l) Clearance under a veranda, porch, deck or balcony: 12 inches minimum.
EXHAUST
CONNECTOR
34ZDV 6/1/18
Содержание 34 Zircon Direct Vent
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......