Thanks for using Malloca
disinfection cabinet
.
Malloca disinfection cabinet keeps clean and dries the tableware and appliance disinfected
with ozone, UV in the right cabinet and sterilize by far infrared in the left cabinet. The
product can kill colon bacillus, staphylococcus and bacteria causing hepatitis. It is an ideal
disinfection cabinet for the restaurant, kindergarten, hotel, dining hall and other places.
Warning
Only when the right door is closed can the disinfection cabinet work normally,
otherwise there will be leak of ozone.
Do not put any other thing than tableware into the disinfection cabinet.
In order to achieve the best disinfection result and avoid burning your hands or
leak of ozone, you are suggested to wait for another 20mins before opening the
door after the sterilizing is finished and do not take out the tableware before they
cool down.
Cannot put the plastic and wooden product into the left cabinet.
High temperature, please be careful not to get burnt.
Special Attention
For the tableware of which heat-resistance is below 75
℃
should not be placed in the
cabinet.
For the tableware of which heat-resistance is below 180
℃
, such as high temperature
resistance plastic materials, silicon rubber product or low temperature resistant glass
products should not be put into the left cabinet.
The tableware of which heat-resistance is between 180
℃
to 250
℃
should be put away
about 100mm from the heat pipe.
Precautions
The power supply socket must be reliably ground. The
user should not change the socket by himself.(Please
Earthen line
refer to picture 1).
The tableware should be dry before putting into the
cabinet and shouldn't be overlapped to obtain the best
sterilizing effect.
Don't touch the glass of the door when it is sterilizing for
avoiding being scalded.
Don't block the Air-off hole.
When the maintenance work is required, the power supply should be turned off first.
Don't put the disinfection cabinet near the tinder and the cloths things are not
allowed to put into, on or beside the cabinet.
Please turn off the power supply after sterilizing or finish cleaning.
As to the special people (like children) are not suitable to use this disinfection cabinet.
How to handle the junk product: for the junk appliances which excess the safety life
or not available with the repair value, the user should take the appliance to the
recycle enterprise, household appliance agent or after-sales service center. The user
is not allow to throw away the junk appliance by themselves